Suppr超能文献

大脑中动脉的高分辨率血管壁磁共振成像:有脂肪抑制和无脂肪抑制的3D CUBE T1加权序列的比较。

High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression.

作者信息

Wu Yejun, Li Fangbing, Wang Yilin, Hu Tianxiang, Xiao Liang

机构信息

The Fourth Affiliated Hospital of China Medical University, China Medical University, Shengyang, Liaoning, China (mainland).

The Fourth Affiliated Hospital of China Medical University, China Medical University, Shenyang, Liaoning, China (mainland).

出版信息

Med Sci Monit. 2020 Nov 7;26:e928931. doi: 10.12659/MSM.928931.

Abstract

BACKGROUND Fat suppression is an important technique in magnetic resonance imaging (MRI). Comprehensive and quantitative assessment of the influence of fat suppression (FS) on T1-weighted imaging of intracranial vessel wall imaging is needed. In this study, we compared the three-dimensional (3D) variable-flip-angle turbo-spin-echo (CUBE) T1-weighted sequence with and without FS to investigate the differences between the 2 sequences in imaging of the middle cerebral artery (MCA) vessel walls. MATERIAL AND METHODS A 3D CUBE T1-weighted sequence with and without FS by 3.0T MRI was used to obtain intracranial vessel wall images of 105 MCA stenosis patients. The image signal intensity, signal-to-noise ratio, and contrast-to-noise ratio were calculated and compared. Two observers evaluated the image quality of the 2 sequences twice, and interobserver and intraobserver consistency were determined. Differences between the 2 sequences in the area of lumen and plaque were compared. RESULTS The signal intensity, signal-to-noise ratio, and contrast-to-noise ratio of the 3D CUBE T1-weighted sequence without FS were higher, whereas the noise level was lower. In terms of subjective scores, the 3D CUBE T1-weighted sequence without FS performed better. No significant difference was observed in the measurement of the vascular lumen area between the 2 sequences, although there were statistically significant differences in the measurement of plaque area (i.e., the measurement obtained with 3D CUBE T1-weighted sequence without FS was larger). CONCLUSIONS 3D CUBE T1-weighted sequence without FS performed better for MCA vessel walls imaging than 3D CUBE T1-weighted sequence with FS.

摘要

背景 脂肪抑制是磁共振成像(MRI)中的一项重要技术。需要对脂肪抑制(FS)对颅内血管壁成像的T1加权成像的影响进行全面和定量评估。在本研究中,我们比较了有无FS的三维(3D)可变翻转角涡轮自旋回波(CUBE)T1加权序列,以研究这两种序列在大脑中动脉(MCA)血管壁成像中的差异。

材料与方法 采用3.0T MRI的有无FS的3D CUBE T1加权序列,获取105例MCA狭窄患者的颅内血管壁图像。计算并比较图像信号强度、信噪比和对比噪声比。两名观察者对这两种序列的图像质量进行了两次评估,并确定了观察者间和观察者内的一致性。比较了两种序列在管腔和斑块面积方面的差异。

结果 无FS的3D CUBE T1加权序列的信号强度、信噪比和对比噪声比更高,而噪声水平更低。在主观评分方面,无FS的3D CUBE T1加权序列表现更好。两种序列在血管管腔面积测量上未观察到显著差异,尽管在斑块面积测量上存在统计学显著差异(即无FS的3D CUBE T1加权序列获得的测量值更大)。

结论 对于MCA血管壁成像,无FS的3D CUBE T1加权序列比有FS的3D CUBE T1加权序列表现更好。