Br J Radiol. 2021 May 1;94(1121):20210145. doi: 10.1259/bjr.20210145. Epub 2021 Mar 25.
This study investigated the diagnostic performance of MinIP images based on three-dimensional variable-flip-angle turbo spin echo weighted imaging (3D CUBE WI) from high-resolution vessel wall magnetic resonance imaging for detecting middle cerebral artery (MCA) stenosis.
A total of 63 consecutive patients were included in this study. MinIP images were reconstructed using 3D CUBE WI as the source images. The degree and length of MCA stenosis were measured on MinIP images and were compared with digital subtraction angiography (DSA) as the reference standard.
The intra- and interobserver agreement for both the rate and length of MCA stenosis were excellent for the MinIP images. There was also excellent agreement in the degree of MCA stenosis calculated using MinIP images and DSA. MinIP images had a high sensitivity, specificity for diagnosing MCA stenosis. There was a good correlation between the two methods for measuring the rate and length of MCA stenosis.
MinIP images based on 3D CUBE WI are highly consistent with DSA for evaluating the degree and length of MCA stenosis.
MinIP images can be produced as a derivative from vessel wall imaging and implemented as an adjunct to vessel wall imaging without extra acquisition time.
本研究旨在探讨基于三维可变翻转角涡轮自旋回波加权成像(3D CUBE WI)的 MinIP 图像对检测大脑中动脉(MCA)狭窄的诊断性能。
本研究共纳入 63 例连续患者。MinIP 图像是使用 3D CUBE WI 作为源图像重建的。在 MinIP 图像上测量 MCA 狭窄的程度和长度,并与数字减影血管造影(DSA)作为参考标准进行比较。
MinIP 图像对 MCA 狭窄率和长度的观察者内和观察者间一致性均为优秀。MinIP 图像计算的 MCA 狭窄程度与 DSA 也具有极好的一致性。MinIP 图像对 MCA 狭窄的诊断具有较高的灵敏度和特异性。两种方法在测量 MCA 狭窄率和长度方面具有良好的相关性。
基于 3D CUBE WI 的 MinIP 图像与 DSA 高度一致,可用于评估 MCA 狭窄的程度和长度。
MinIP 图像可以作为血管壁成像的衍生图像,并在不增加采集时间的情况下作为血管壁成像的辅助手段。