Physiol Meas. 2020 Nov 6;41(10):104002. doi: 10.1088/1361-6579/abb320.
Slow breathing is a relaxation exercise recommended for lowering blood pressure (BP). Biofeedback may improve patient adherence and enhance BP lowering effects. Since the pulse arrival time (PAT) is inversely proportional to BP, it can be used to estimate BP changes.
In this pilot study, 30 patients (age 62.9 (SD 7.7) years, 11 F/19 M, Sys. BP 133.0 (SD 17.1) mmHg, Dia. BP 83.8 (SD 10.6) mmHg) performed a device-guided slow breathing exercise. PAT was measured by ECG and plethysmography and immediately presented to the patient, and respiratory sinus arrhythmia (RSA) was calculated retrospectively to measure the adherence to the instructed respiratory rate.
Respiratory rate was 13.6 (SD 1.9) bpm at baseline and 5.4 (SD 1.0) bpm during guided breathing. PAT continuously and progressively increased from 231.5 (SD 20.3) to 237.3 (SD 18.5) ms (p [Formula: see text] 0.001). The median deviation of RSA from the guided respiratory rate was 0.06 (IQR 0.19) bpm. In three patients, a deviation of > 0.20 bpm was detected, and two of them showed no increase in PAT. In total, 25 patients responded with increase in PAT.
In this pilot study we have shown that biofeedback of PAT and RSA are feasible and can further improve motivation and adherence. Furthermore, we have shown that the exercise increased PAT, which indicates a reduction in BP. Due to its ease of use, this method is ideal for home use and self-monitoring.
缓慢呼吸是一种被推荐用于降低血压(BP)的放松练习。生物反馈可能会提高患者的依从性并增强降压效果。由于脉搏到达时间(PAT)与 BP 成反比,因此可以用来估计 BP 的变化。
在这项初步研究中,30 名患者(年龄 62.9(SD 7.7)岁,11 名女性/19 名男性,Sys.BP 为 133.0(SD 17.1)mmHg,Dia.BP 为 83.8(SD 10.6)mmHg)进行了设备引导的缓慢呼吸练习。PAT 通过心电图和体积描记法测量,并立即呈现给患者,并且计算呼吸窦性心律失常(RSA)来回顾性测量对指示呼吸频率的依从性。
基线时呼吸频率为 13.6(SD 1.9)bpm,引导呼吸时为 5.4(SD 1.0)bpm。PAT 连续且逐渐从 231.5(SD 20.3)增加到 237.3(SD 18.5)ms(p [Formula: see text] 0.001)。RSA 与指导呼吸频率的中位数偏差为 0.06(IQR 0.19)bpm。在三名患者中,检测到偏差> 0.20bpm,其中两名患者的 PAT 没有增加。总共 25 名患者的 PAT 增加。
在这项初步研究中,我们已经证明了 PAT 和 RSA 的生物反馈是可行的,可以进一步提高动机和依从性。此外,我们已经证明该运动增加了 PAT,这表明 BP 降低。由于其易于使用,这种方法非常适合家庭使用和自我监测。