Suppr超能文献

处理方法和储存时间会影响红细胞单位中外泌体的计数。

Processing methods and storage duration impact extracellular vesicle counts in red blood cell units.

机构信息

University Bourgogne Franche-Comté, INSERM, Etablissement Français du sang Bourgogne Franche Comté, Unité Mixte de Recherche 1098, Interactions Hôte-Greffon-Tumeur, Ingénierie Cellulaire et Génique, Besançon, France.

INSERM Centre Investigation Clinique 1431, Centre Hospitalier Universitaire (CHU) Besançon, Besançon, France.

出版信息

Blood Adv. 2020 Nov 10;4(21):5527-5539. doi: 10.1182/bloodadvances.2020001658.

Abstract

Extracellular vesicles (EVs) are active components of red blood cell (RBC) concentrates and may be associated with beneficial and adverse effects of transfusion. Elucidating controllable factors associated with EV release in RBC products is thus important to better manage the quality and properties of RBC units. Erythrocyte-derived EVs (EEVs) and platelet-derived EVs (PEVs) were counted in 1226 RBC units (administered to 280 patients) using a standardized cytometry-based method. EV size and CD47 and annexin V expression were also measured. The effects of donor characteristics, processing methods, and storage duration on EV counts were analyzed by using standard comparison tests, and analysis of covariance was used to determine factors independently associated with EV counts. PEV as well as EEV counts were higher in whole-blood-filtered RBC units compared with RBC-filtered units; PEV counts were associated with filter type (higher with filters associated with higher residual platelets), and CD47 expression was higher on EEVs in RBC units stored longer. Multivariate analysis showed that EEV counts were strongly associated with filter type (P < .0001), preparation, and storage time (+25.4 EEV/µL per day [P = .01] and +42.4 EEV/µL per day [P < .0001], respectively). The only independent factor associated with PEV counts was the residual platelet count in the unit (+67.1 PEV/µL; P < .0001). Overall, processing methods have an impact on EV counts and characteristics, leading to large variations in EV quantities transfused into patients. RBC unit processing methods might be standardized to control the EV content of RBC units if any impacts on patient outcomes can be confirmed. The IMIB (Impact of Microparticles in Blood) study is ancillary to the French ABLE (Age of Transfused Blood in Critically Ill Adults) trial (ISRCTN44878718).

摘要

细胞外囊泡 (EVs) 是红细胞浓缩物中的活性成分,可能与输血的有益和不利影响有关。因此,阐明与 RBC 产品中 EV 释放相关的可控因素对于更好地管理 RBC 单位的质量和特性非常重要。使用标准化的基于细胞术的方法在 1226 个 RBC 单位(输注给 280 名患者)中计数红细胞衍生的 EV (EEV) 和血小板衍生的 EV (PEV)。还测量了 EV 的大小和 CD47 及膜联蛋白 V 的表达。使用标准比较检验分析供体特征、处理方法和储存时间对 EV 计数的影响,并使用协方差分析确定与 EV 计数独立相关的因素。与 RBC 过滤单位相比,全血过滤 RBC 单位中的 PEV 和 EEV 计数更高;PEV 计数与过滤器类型相关(与残留血小板更高的过滤器相关更高),并且在储存时间较长的 RBC 单位中,EEV 上的 CD47 表达更高。多变量分析表明,EEV 计数与过滤器类型(P <.0001)、制备和储存时间密切相关(每天增加 25.4 个 EEV/µL [P =.01] 和每天增加 42.4 个 EEV/µL [P <.0001])。唯一与 PEV 计数独立相关的因素是单位中的残留血小板计数(增加 67.1 个 PEV/µL;P <.0001)。总体而言,处理方法对 EV 计数和特征有影响,导致输注给患者的 EV 数量存在很大差异。如果可以证实对患者结局有任何影响,可能会标准化 RBC 单位的处理方法来控制 RBC 单位的 EV 含量。IMIB(血液中小粒子的影响)研究是法国 ABLE(危重症成人输注血液的年龄)试验(ISRCTN44878718)的辅助研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1600/7656935/5ea7bc7c838f/advancesADV2020001658absf1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验