Suppr超能文献

同时 LC-MS/MS 法测定结直肠癌患者术后早期血浆中游离 3-硝基-l-酪氨酸、3-氯-l-酪氨酸和 3-溴-l-酪氨酸。

Simultaneous LC-MS/MS-Based Quantification of Free 3-Nitro-l-tyrosine, 3-Chloro-l-tyrosine, and 3-Bromo-l-tyrosine in Plasma of Colorectal Cancer Patients during Early Postoperative Period.

机构信息

Department of Medical Biochemistry, Wroclaw Medical University, 50-368 Wroclaw, Poland.

Department of Oncological Surgery, Regional Specialist Hospital, 51-124 Wroclaw, Poland.

出版信息

Molecules. 2020 Nov 5;25(21):5158. doi: 10.3390/molecules25215158.

Abstract

Quantification with satisfactory specificity and sensitivity of free 3-Nitro-l-tyrosine (3-NT), 3-Chloro-l-tyrosine (3-CT), and 3-Bromo-l-tyrosine (3-BT) in biological samples as potential inflammation, oxidative stress, and cancer biomarkers is analytically challenging. We aimed at developing a liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for their simultaneous analysis without an extract purification step by solid-phase extraction. Validation of the developed method yielded the following limits of detection (LOD) and quantification (LOQ) for 3-NT, 3-BT, and 3-CT: 0.030, 0.026, 0.030 ng/mL (LODs) and 0.100, 0.096, 0.098 ng/mL (LOQs). Coefficients of variation for all metabolites and tested concentrations were <10% and accuracy was within 95-105%. Method applicability was tested on colorectal cancer patients during the perioperative period. All metabolites were significantly higher in cancer patients than healthy controls. The 3-NT was significantly lower in advanced cancer and 3-BT showed a similar tendency. Dynamics of 3-BT in the early postoperative period were affected by type of surgery and presence of surgical site infections. In conclusion, a sensitive and specific LC-MS/MS method for simultaneous quantification of free 3-NT, 3-BT, and 3-CT in human plasma has been developed.

摘要

定量检测生物样本中游离 3-硝基-L-酪氨酸 (3-NT)、3-氯-L-酪氨酸 (3-CT) 和 3-溴-L-酪氨酸 (3-BT) 的特异性和灵敏度达到满意水平,作为炎症、氧化应激和癌症生物标志物具有分析挑战性。我们旨在开发一种无需固相萃取提取纯化步骤即可同时分析这些物质的基于液相色谱-串联质谱 (LC-MS/MS) 的方法。所开发方法的验证得到了以下 3-NT、3-BT 和 3-CT 的检测限 (LOD) 和定量限 (LOQ):0.030、0.026、0.030ng/mL(LOD)和 0.100、0.096、0.098ng/mL(LOQ)。所有代谢物和测试浓度的变异系数均<10%,准确度在 95-105%范围内。该方法的适用性在围手术期的结直肠癌患者中进行了测试。与健康对照组相比,所有代谢物在癌症患者中均显著升高。晚期癌症患者的 3-NT 显著降低,3-BT 也表现出类似的趋势。3-BT 在术后早期的动态变化受手术类型和手术部位感染的影响。总之,已经开发出一种灵敏且特异的 LC-MS/MS 方法,用于同时定量检测人血浆中的游离 3-NT、3-BT 和 3-CT。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7822/7663926/9e86c6f1b040/molecules-25-05158-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验