Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan.
Second Department of Orthopaedic Surgery, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan.
Eur J Orthop Surg Traumatol. 2021 May;31(4):743-753. doi: 10.1007/s00590-020-02828-7. Epub 2020 Nov 10.
Short stems have recently become popular in total hip arthroplasty. Previous studies aimed at elucidating the efficacy of short stems did not eliminate the influence of other factors aside from stem length. This study aimed to evaluate the usefulness of short stems compared with that of standard-length stems that have the same proximal morphology, surface coating, and material.
This was a prospective randomized study comparing 5-year midterm outcomes in 29 patients who underwent one-stage bilateral total hip arthroplasty with short and standard-length stems inserted in each of the two femurs. Clinical, radiographical, and dual-energy X-ray absorptiometry outcomes were compared.
No significant differences were found in perioperative and radiographic characteristics (femoral neck anteversion, flare index, operation sequence, operation side, operation time, stem anteversion, and stem alignment). The number of joints with complications, appearance of radiopaque lines around the stems, or bone mineral density changed in stem regions 5 years postoperatively. However, greater micromotion of the stem was seen on the side of the short stem. Satisfactory improvement in hip function was seen on both sides.
Based on the 5-year midterm outcomes, both stems obtained satisfactory clinical outcomes despite the greater micromotion with short stems. Both stems attained bone ingrowth fixation. Moreover, the stems were not significantly different in terms of stress shielding; however, further long-term studies (> 5 years) are required to validate our findings related to stress shielding.
短柄最近在全髋关节置换术中变得流行。之前旨在阐明短柄疗效的研究并没有消除除柄长以外的其他因素的影响。本研究旨在评估与具有相同近端形态、表面涂层和材料的标准长度柄相比,短柄的有用性。
这是一项前瞻性随机研究,比较了 29 例患者的 5 年中期结果,这些患者在每侧股骨中分别插入短柄和标准长度柄进行一期双侧全髋关节置换术。比较了临床、影像学和双能 X 线吸收法的结果。
在围手术期和影像学特征(股骨颈前倾角、外展指数、手术顺序、手术侧、手术时间、柄前倾角和柄对线)方面无显著差异。在术后 5 年,关节并发症的数量、柄周围出现不透射线线或骨密度变化的情况发生了变化。然而,在短柄侧观察到更多的柄微动。两侧髋关节功能均有满意的改善。
根据 5 年中期结果,尽管短柄的微动更大,但两种柄均获得了满意的临床结果。两种柄均获得了骨长入固定。此外,在应力屏蔽方面,两种柄没有显著差异;然而,需要进行更长时间(>5 年)的研究来验证我们关于应力屏蔽的发现。