Saline agglutination tests (SATs) are widely recommended for diagnosis of immune-mediated hemolytic anemia in dogs, but there are frequent false-positive results.
Specificity of SATs will improve at higher saline-to-blood ratios.
One hundred fifty dogs treated at a veterinary referral hospital with hematocrits ≤30%.
Prospective diagnostic accuracy study. Immune-mediated hemolysis (IMH) was considered present if a gel direct antiglobulin test (DAT) was positive and there was clinical evidence of hemolysis (n = 9), absent if another mechanism for anemia was identified and the DAT was negative or there was no hemolysis (n = 138), and if IMH status was unclear, dogs were excluded (n = 3). Saline agglutination tests were prepared at 1 : 1, 4 : 1, 9 : 1, and 49 : 1 saline-to-blood ratios, and microscopic agglutination was considered a positive result.
Specificity for IMH increased from 29% (95% confidence interval 20-38) at a 1 : 1 dilution to 97% (93-99) at a 49 : 1 dilution. Sensitivity was 88% (47-100) at 1 : 1 and 4 : 1 dilutions and 67% (30-93%) at 9 : 1 and 49 : 1 dilutions. Diagnostic accuracy increased from 33% (24-42) at 1 : 1 dilution to 95% (90-98) at 49 : 1 dilution.
If performed using a 49 : 1 saline-to-blood ratio, SATs achieve high specificity for IMH. Based on a gold standard of positive DAT and evidence of hemolysis, lower saline-to-blood ratio results should not be used because false-positive results are common.
盐水凝集试验(SATs)广泛应用于犬免疫介导性溶血性贫血的诊断,但常出现假阳性结果。
提高盐水与血液的比例可提高 SATs 的特异性。
在一家兽医转诊医院接受治疗、血细胞比容≤30%的 150 只狗。
前瞻性诊断准确性研究。如果凝胶直接抗球蛋白试验(DAT)阳性且有溶血性贫血的临床证据,则认为存在免疫介导性溶血性贫血(IMH)(n=9);如果确定了其他贫血机制且 DAT 阴性或无溶血,则认为不存在 IMH(n=138);如果 IMH 状态不明确,则排除狗(n=3)。SATs 分别在 1:1、4:1、9:1 和 49:1 盐水与血液的比例下制备,显微镜凝集被认为是阳性结果。
在 1:1 稀释度时,IMH 的特异性为 29%(95%置信区间 20-38),在 49:1 稀释度时特异性为 97%(93-99)。在 1:1 和 4:1 稀释度时,敏感性为 88%(47-100),在 9:1 和 49:1 稀释度时敏感性为 67%(30-93%)。在 1:1 稀释度时,诊断准确性为 33%(24-42),在 49:1 稀释度时,诊断准确性为 95%(90-98)。
如果使用 49:1 的盐水与血液的比例进行 SATs,SATs 对 IMH 具有高特异性。根据 DAT 阳性和溶血证据的金标准,不应使用较低的盐水与血液比例结果,因为假阳性结果很常见。