Suppr超能文献

犬血样稀释对免疫介导性溶血盐水凝集试验特异性的影响。

Effect of dilution of canine blood samples on the specificity of saline agglutination tests for immune-mediated hemolysis.

机构信息

College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas, USA.

Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas, USA.

出版信息

J Vet Intern Med. 2020 Nov;34(6):2374-2383. doi: 10.1111/jvim.15945. Epub 2020 Nov 10.

Abstract

BACKGROUND

Saline agglutination tests (SATs) are widely recommended for diagnosis of immune-mediated hemolytic anemia in dogs, but there are frequent false-positive results.

OBJECTIVES

Specificity of SATs will improve at higher saline-to-blood ratios.

ANIMALS

One hundred fifty dogs treated at a veterinary referral hospital with hematocrits ≤30%.

METHODS

Prospective diagnostic accuracy study. Immune-mediated hemolysis (IMH) was considered present if a gel direct antiglobulin test (DAT) was positive and there was clinical evidence of hemolysis (n = 9), absent if another mechanism for anemia was identified and the DAT was negative or there was no hemolysis (n = 138), and if IMH status was unclear, dogs were excluded (n = 3). Saline agglutination tests were prepared at 1 : 1, 4 : 1, 9 : 1, and 49 : 1 saline-to-blood ratios, and microscopic agglutination was considered a positive result.

RESULTS

Specificity for IMH increased from 29% (95% confidence interval 20-38) at a 1 : 1 dilution to 97% (93-99) at a 49 : 1 dilution. Sensitivity was 88% (47-100) at 1 : 1 and 4 : 1 dilutions and 67% (30-93%) at 9 : 1 and 49 : 1 dilutions. Diagnostic accuracy increased from 33% (24-42) at 1 : 1 dilution to 95% (90-98) at 49 : 1 dilution.

CONCLUSIONS AND CLINICAL IMPORTANCE

If performed using a 49 : 1 saline-to-blood ratio, SATs achieve high specificity for IMH. Based on a gold standard of positive DAT and evidence of hemolysis, lower saline-to-blood ratio results should not be used because false-positive results are common.

摘要

背景

盐水凝集试验(SATs)广泛应用于犬免疫介导性溶血性贫血的诊断,但常出现假阳性结果。

目的

提高盐水与血液的比例可提高 SATs 的特异性。

动物

在一家兽医转诊医院接受治疗、血细胞比容≤30%的 150 只狗。

方法

前瞻性诊断准确性研究。如果凝胶直接抗球蛋白试验(DAT)阳性且有溶血性贫血的临床证据,则认为存在免疫介导性溶血性贫血(IMH)(n=9);如果确定了其他贫血机制且 DAT 阴性或无溶血,则认为不存在 IMH(n=138);如果 IMH 状态不明确,则排除狗(n=3)。SATs 分别在 1:1、4:1、9:1 和 49:1 盐水与血液的比例下制备,显微镜凝集被认为是阳性结果。

结果

在 1:1 稀释度时,IMH 的特异性为 29%(95%置信区间 20-38),在 49:1 稀释度时特异性为 97%(93-99)。在 1:1 和 4:1 稀释度时,敏感性为 88%(47-100),在 9:1 和 49:1 稀释度时敏感性为 67%(30-93%)。在 1:1 稀释度时,诊断准确性为 33%(24-42),在 49:1 稀释度时,诊断准确性为 95%(90-98)。

结论和临床意义

如果使用 49:1 的盐水与血液的比例进行 SATs,SATs 对 IMH 具有高特异性。根据 DAT 阳性和溶血证据的金标准,不应使用较低的盐水与血液比例结果,因为假阳性结果很常见。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e8d0/7694812/626246bcea63/JVIM-34-2374-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验