To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI  0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer.

摘要

为了研究客观 CBCT 图像参数与离体根管工作长度确定准确性之间的潜在相关性。使用七种不同 CBCT 机中的特定体模检查了对比噪声比 (CNR) 和空间分辨率 (SR) 等基本客观图像参数。对七名有经验的观察者进行了指导和校准。为每个观察者和观察顺序随机化了 CBCT 的顺序。为了评估操作者内的可重复性,在六周内以 CBCT 图像的随机顺序重复了该过程。多变量分析(MANOVA)并未显示组合图像质量因素 CNR 和 SR 对测量准确性有任何影响。两次观察之间的操作者间可重复性较差,第一次观察的组内相关系数 (ICC) 平均值为 0.48(95%CI 0.38,0.59),第二次观察的 ICC 平均值为 0.40(95%CI 0.30,0.51)。两次观察之间所有观察者的操作者内可重复性仅为中度,ICC 平均值为 0.58(95%CI 0.52 至 0.64)。在研究的限制范围内,客观图像质量测量和曝光参数似乎对 CBCT 扫描中确定根管长度的准确性没有显著影响。方差的主要因素是观察者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0929/7655868/a44fa18abb1d/41598_2020_76424_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验