Suppr超能文献

优化在炎热条件下爆炸物处理行动中所穿相变材料背心的使用

Optimizing the Use of Phase Change Material Vests Worn During Explosives Ordnance Disposal Operations in Hot Conditions.

作者信息

Davey Sarah Lee, Lee Ben James, Smith Mark, Oldroyd Mark, Thake Charles Doug

机构信息

Occupational and Environmental Physiology Group, Centre for Sport, Exercise and Life Sciences (CSELS), Faculty of Health and Life Sciences, Coventry University, Coventry, United Kingdom.

United Shield International, Andover, United Kingdom.

出版信息

Front Physiol. 2020 Oct 29;11:573521. doi: 10.3389/fphys.2020.573521. eCollection 2020.

Abstract

Phase change material (PCM) cooling garments' efficacy is limited by the duration of cooling provided. The purpose of this study was to evaluate the effect of replacing a PCM vest during a rest period on physiological and perceptual responses during explosive ordnance disposal (EOD) related activity. Six non-heat acclimated males undertook three trials (consisting of 2 × 3 × 16.5 min activity cycles interspersed with one 10 min rest period) in 40°C, 12% relative humidity whilst wearing a ≈38 kg EOD suit. Participants did not wear a PCM cooling vest (NoPCM); wore one PCM vest throughout (PCM1) or changed the PCM vest in the 10 min rest period (PCM2). Rectal temperature (T ), mean skin temperature (T ), heart rate (HR), Physiological Strain Index (PSI), ratings of perceived exertion, temperature sensation and thermal comfort were compared at the end of each activity cycle and at the end of the trial. Data displayed as mean [95% CI]. After the rest period, a rise in T was attenuated in PCM2 compared to NoPCM and PCM1 (-0.57 [-0.95, -0.20]°C and -0.46 [-0.81, -0.11]°C, respectively). A rise in HR and T was also attenuated in PCM2 compared to NoPCM and PCM1 (-23 [-29, -16] beats⋅min and -17 [-28, -6.0] beats⋅min; -0.61 [-1.21, -0.10]°C and -0.89 [-1.37, -0.42]°C, respectively). Resulting in PSI being lower in PCM2 compared to NoPCM and PCM1 (-2.2 [-3.1, -1.4] and -0.8 [-1.3,-0.4], respectively). More favorable perceptions were also observed in PCM2 vs. both NoPCM and PCM1 ( < 0.01). Thermal perceptual measures were similar between NoPCM and PCM1 and the rise in T after the rest period tended to be greater in PCM1 than NoPCM. These findings suggest that replacing a PCM vest better attenuates rises in both physiological and perceptual strain compared to when a PCM vest is not replaced. Furthermore, not replacing a PCM vest that has exhausted its cooling capacity, can increase the level of heat strain experienced by the wearer.

摘要

相变材料(PCM)冷却服装的功效受其提供冷却时间的限制。本研究的目的是评估在休息期间更换PCM背心对爆炸物处理(EOD)相关活动期间生理和感知反应的影响。六名未进行热适应的男性在40°C、相对湿度12%的环境中,穿着约38公斤的EOD防护服进行了三项试验(包括2×3×16.5分钟的活动周期,中间穿插一个10分钟的休息期)。参与者未穿PCM冷却背心(无PCM组);全程穿着一件PCM背心(PCM1组)或在10分钟休息期更换PCM背心(PCM2组)。在每个活动周期结束时和试验结束时,比较直肠温度(T )、平均皮肤温度(T )、心率(HR)、生理应变指数(PSI)、主观用力感觉评分、温度感觉和热舒适度。数据以平均值[95%置信区间]表示。休息期后,与无PCM组和PCM1组相比,PCM2组T 的升高有所减弱(分别为-0.57[-0.95,-0.20]°C和-0.46[-0.81,-0.11]°C)。与无PCM组和PCM1组相比,PCM

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cb04/7658344/21a1d9752a0e/fphys-11-573521-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验