BACKGROUND

Peroxide value is used as an indicator of oxidative degradation, off flavor, and rancidity in fat. Traditional methods are dependent on a fat extraction step to extract fat for subsequent titration of peroxides. The SafTest Peroxide Test offers a direct measurement of the peroxide value of vegetable oils, animal fats, meat meal and fish meal products, and potato chips, crackers, and other processed grain-based snack products using micro-analytical and membrane separation principles.

OBJECTIVE

The study objective is to validate the SafTest Peroxide Test in an internal study, two contracted studies, and an independent laboratory study.

METHOD

Calibration, LOQ, robustness, selectivity, matrix, shelf life, and lot-to-lot stability were evaluated.

RESULTS

The practical dynamic range of the calibration is 0.00 to 0.20 meq/kg. LOQ was determined as 0.02 meq/kg for liquids analyzed neat and 0.08 to 0.46 meq/kg for dry matrixes requiring a 1:4 to a 1:8 dilution. SafTest Peroxide Test relative standard deviations of repeatability (RSDr) averaged 1-13% compared to AOCS Cd 8-53 RSDr% of 1-15% and demonstrated average recoveries of 95.7, 91.5, and 105.2% of the AOCS Cd 8-53 results for olive oil, meat meal and fish, and animal fat and oils, respectively.

CONCLUSIONS

The SafTest Peroxide Test is an acceptable alternative to AOCS Cd 8-53 and AOCS Cd 8 b-90 for the measurement of peroxide value in oils, fats, meat meal, fish meal, and snack products.

HIGHLIGHTS

The SafTest Peroxide Test uses small reagent volumes, eliminates fat extraction, and provides rapid and standardized procedures for the detection of peroxide.

摘要

背景

过氧化物值被用作脂肪氧化降解、异味和酸败的指标。传统方法依赖于脂肪提取步骤来提取脂肪,以便随后对过氧化物进行滴定。SafTest 过氧化物测试使用微分析和膜分离原理,直接测量植物油、动物脂肪、肉粉和鱼粉产品以及薯片、饼干和其他加工谷物基零食产品的过氧化物值。

目的

本研究旨在通过内部研究、两项委托研究和独立实验室研究验证 SafTest 过氧化物测试。

方法

评估了校准、LOQ、稳健性、选择性、基质、保质期和批间稳定性。

结果

校准的实际动态范围为 0.00 至 0.20meq/kg。LOQ 分别确定为分析纯液体的 0.02meq/kg 和需要 1:4 至 1:8 稀释的干基质的 0.08 至 0.46meq/kg。与 AOCS Cd 8-53 的重复性(RSDr)的 1-15%相比,SafTest 过氧化物测试的相对标准偏差(RSDr)平均为 1-13%,并且分别显示橄榄油、肉粉和鱼以及动物脂肪和油的 AOCS Cd 8-53 结果的平均回收率为 95.7%、91.5%和 105.2%。

结论

SafTest 过氧化物测试是 AOCS Cd 8-53 和 AOCS Cd 8 b-90 测量油、脂肪、肉粉、鱼粉和零食产品中过氧化物值的可接受替代品。

要点

SafTest 过氧化物测试使用小体积试剂,消除了脂肪提取,并提供了快速标准化的过氧化物检测程序。