BACKGROUND

The Official American Oil Chemists Society (AOCS) Standard Procedure Aa 4-38, AOCS Standard Procedure Am 5-04, ISO 11085:2015, and similar methods are based on extraction of fats from food products using organic solvents. These methods require large volumes of organic solvents and up to 18-hour extractions. The SafTest Percent Fat measures fat content as "total triglycerides" in solubilized snack products and meals using micro-analytical and membrane separation principles.

OBJECTIVE

The study objective is to validate the SafTest Percent Fat in an internal study and an independent laboratory study.

METHOD

Comparability to AOCS Standard Procedure Aa 4-38 or AOCS Standard Procedure Am 5-04, LOQ, selectivity, robustness, stability, and consistency were determined.

RESULTS

Mean recoveries from replicate analyses of SafTest control samples at three concentrations yielded 101 to 103%. The relative standard deviations of repeatability (RSDr) were below 5%. Studies of meat meals and snacks analyzed using the SafTest Percent Fat demonstrated RSDr of 2.3 to 5.6% compared to 2.6 to 4.9% for AOCS Aa 4-38. The method demonstrated average recoveries ranging from 88.8 to 116.2% compared to the AOCS methods results performed in two contract laboratory studies and an independent laboratory validation.

CONCLUSIONS

The SafTest Percent Fat test can determine fat content in meals and snack matrices with accuracy and precision comparable to results from AOCS Aa 4-38 and AOCS Am 5-04.

HIGHLIGHTS

The SafTest Percent Fat test uses small reagent volumes, instrumental analysis, easy-to-use standardized procedures, and rapid analysis times for fat content determination.

摘要

背景

美国油化学家协会(AOCS)官方标准程序 Aa 4-38、AOCS 标准程序 Am 5-04、ISO 11085:2015 以及类似的方法都是基于使用有机溶剂从食品中提取脂肪。这些方法需要大量的有机溶剂,并且需要长达 18 小时的提取时间。SafTest 百分脂肪率使用微分析和膜分离原理,通过溶解的小吃产品和膳食中的“总甘油三酯”来测量脂肪含量。

目的

本研究旨在通过内部研究和独立实验室研究对 SafTest 百分脂肪率进行验证。

方法

对 SafTest 控制样品进行三个浓度的重复分析,确定可比性、LOQ、选择性、稳健性、稳定性和一致性。

结果

SafTest 控制样品三个浓度的重复分析的平均回收率为 101%至 103%。重复性(RSDr)的相对标准偏差低于 5%。使用 SafTest 百分脂肪率分析肉餐和小吃的研究表明,与 AOCS Aa 4-38 的 2.6%至 4.9%相比,RSDr 为 2.3%至 5.6%。该方法的平均回收率范围为 88.8%至 116.2%,与两项合同实验室研究和一项独立实验室验证中 AOCS 方法的结果相比。

结论

SafTest 百分脂肪率测试可以准确、精确地测定膳食和小吃基质中的脂肪含量,结果与 AOCS Aa 4-38 和 AOCS Am 5-04 相似。

重点

SafTest 百分脂肪率测试使用小体积的试剂、仪器分析、易于使用的标准化程序以及快速的脂肪含量分析时间。