Suppr超能文献

循环功率计作为残疾患者峰值有氧能力测量指标的意义。

Significance of Cycle Ergometer as a Measure of Peak Aerobic Capacity in the Disabled.

机构信息

Department of Medicine, Graduate School, Jeju National University, Jeju, Korea.

Department of Rehabilitation Medicine, Jeju National University, College of Medicine, Jeju, Korea.

出版信息

J Stroke Cerebrovasc Dis. 2021 Feb;30(2):105477. doi: 10.1016/j.jstrokecerebrovasdis.2020.105477. Epub 2020 Nov 26.

Abstract

BACKGROUND

To compare different physiological responses between treadmill and cycle ergometer in stroke patients in regard to community ambulation, and to determine strong predictors of equipment-dependent VO and its related factors among physical fitness parameters and finally to establish the significance of cycle ergometer as a measure of VO in the disabled according to gait function.

METHODS

Sixty-three stroke survivors were enrolled in this study and were grouped according to the gait speed (32 non-community ambulators <0.8 m/s:31 community ambulators ≥0.8 m/s). All participants performed exercise stress test (EST) with treadmill and cycle ergometer and rehabilitation function tests.

RESULTS

Community ambulators achieved higher VO by treadmill, but non-community ambulators showed similar VO between treadmill and cycle ergometer due to gait problems. The gait speed and endurance were strong predictors of difference of peak aerobic capacity between treadmill and cycle ergometer (multiple regression analysis, adjusted R=0.458).

CONCLUSION

Cycle ergometer might be more appropriate for non-community ambulatory stroke patients to assess the peak aerobic capacity. Gait speed and gait distance could affect equipment-dependent cardiopulmonary performance significantly in the disabled. Therefore, the careful consideration of comprehensive and objective physical function including gait endurance, and speed and prescription of appropriate exercise intensity and equipment depending on the severity should be needed to improve the cardiopulmonary fitness and physical function adequately in stroke rehabilitation.

摘要

背景

为了比较在社区活动方面,跑步机和功率自行车在脑卒中患者中不同的生理反应,确定与运动能力相关的、对设备依赖的 VO 的强预测因子及其相关因素,并根据步态功能确定功率自行车作为残疾患者 VO 测量的重要性。

方法

本研究纳入 63 名脑卒中幸存者,并根据步行速度(非社区步行者<0.8m/s:32 名;社区步行者≥0.8m/s:31 名)进行分组。所有参与者均进行跑步机和功率自行车运动应激测试(EST)以及康复功能测试。

结果

由于步态问题,社区步行者在跑步机上的 VO 更高,但非社区步行者在跑步机和功率自行车上的 VO 相似。(多元回归分析,调整后的 R=0.458)。

结论

对于非社区步行的脑卒中患者,功率自行车可能更适合评估峰值有氧能力。在残疾患者中,步态速度和步态距离会显著影响设备依赖的心肺功能。因此,在脑卒中康复中,需要全面考虑包括步态耐力、速度在内的综合客观身体功能,并根据严重程度适当开出运动强度和设备处方,以充分提高心肺功能和身体功能。