Department of Restorative, Preventive and Paediatric Dentistry, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland.
Department of Periodontology and Operative Dentistry, University Medical Center, Johannes Gutenberg University Mainz, Mainz, Germany.
Clin Oral Investig. 2021 May;25(5):3207-3215. doi: 10.1007/s00784-020-03651-4. Epub 2020 Dec 7.
The purpose of this investigation was to recognize pulp sensitivity changes in teeth receiving orthodontic treatment by means of an electric pulp tester (Vitality Scanner Model 2006; Kerr Corporation, Brea CA, USA).
An electric stimulus response threshold of eight teeth in 22 patients was measured prior to positioning orthodontic attachments, immediately before ligation of a nickel titanium archwire, immediately after ligation of a stainless steel archwire and 9 to 15 months after having achieved the clinical purposes established with the nickel titanium archwires. The first measurement served as baseline.
All teeth responded to an electrical stimulus at all times. No statistical differences were observed between the response thresholds obtained at different treatment times. The mean response threshold of the second measurement showed a decreasing response threshold tendency when compared with those of the baseline measurement. The mean response threshold of the third measurement showed an increasing tendency when compared with those of the baseline measurement. The first maxillary incisor and canine showed the lowest decreasing response threshold after the second measurement and the highest increasing response threshold after the third measurement. Less noticeable, but similar decreasing and increasing response threshold tendencies were observed in all other teeth after the second and third measurements, respectively.
The results obtained in this investigation suggest that pulp sensitivity can be monitored during orthodontic treatment by means of an electric pulp tester.
The importance of monitoring the pulp status during orthodontic treatment.
本研究旨在通过电活力测试仪(Vitality Scanner Model 2006;美国 Kerr 公司,Brea CA)识别正畸治疗中牙髓的敏感性变化。
在定位正畸附件之前、结扎镍钛弓丝之前、结扎不锈钢弓丝之后以及镍钛弓丝达到临床目的后 9 至 15 个月,测量 22 名患者的 8 颗牙齿的电刺激反应阈值。第一次测量作为基线。
所有牙齿在所有时间都对电刺激有反应。在不同治疗时间获得的反应阈值之间未观察到统计学差异。与基线测量相比,第二次测量的平均反应阈值显示出逐渐降低的趋势。与基线测量相比,第三次测量的平均反应阈值显示出逐渐升高的趋势。上颌第一前磨牙和尖牙在第二次测量后表现出最低的反应阈值降低,在第三次测量后表现出最高的反应阈值升高。其他牙齿在第二次和第三次测量后分别表现出不太明显但类似的反应阈值降低和升高趋势。
本研究的结果表明,电活力测试仪可用于监测正畸治疗中的牙髓敏感性。
监测正畸治疗中牙髓状况的重要性。