Suppr超能文献

糖尿病患者唾液中的常见唾液蛋白 1(II)。

Common Salivary Protein 1 in Saliva of Diabetes Patients (II).

出版信息

Clin Lab. 2020 Dec 1;66(12). doi: 10.7754/Clin.Lab.2020.200327.

Abstract

BACKGROUND

Human common salivary protein 1 (CSP1) is one of a variety of molecules in saliva but its function remains to be determined. The gold standard method for diagnosis of diabetes mellitus (DM) is to check levels of glucose or HbA1C in plasma or serum. The purpose of this study was to examine whether Salivary CSP1 concentration would be useful alternative for DM diagnosis.

METHODS

The qualities of monoclonal antibodies (mAbs) to recombinant human CSP1 (rhCSP1) were tested by western blotting (WB) and immunohistochemistry. A sandwich ELISA was fabricated with the qualified capture and detector mAbs for measurement of CSP1 level in saliva. CSP1 levels of healthy adults and DM patients were measured by the sandwich ELISA and their results were statistically analyzed by Student's t-test. The receiver operating characteristic (ROC) curve was constructed and the area under the curve (AUC) was calculated.

RESULTS

The tested mAbs recognized a 27-kDa CSP1 of saliva in WB and stained only a salivary gland in immunohistochemistry. Pearson's correlation coefficient with standard curve between OD450nm value vs. CSP level showed good linearity (r2 = 0.995). The median values (25th to 75th percentiles) of saliva CSP1 in 10 healthy adults and 18 DM patients using the sandwich ELISA were 3.92 µg/mL (3.15 - 4.02) and 4.35 µg/mL (3.94 - 5.11), respectively. Statistically, there was a significant difference of CSP1 level in two groups (p = 0.026). The sensitivity value of CSP1 was 64.71 while the specificity value was 88.89 with 0.784 of AUC (p = 0.003). These results suggested that the fabricated sandwich ELISA was a good diagnostic test tool for discriminating DM patients from healthy individuals.

CONCLUSIONS

The present data showed a significant increase of CSP1 levels for DM patients compared with control group, indicating that CSP1 level in saliva could be used as a potential biomarker of detection or screening of DM patients. However, further studies are necessary to provide scientific and clinical validation.

摘要

背景

人唾液蛋白 1(CSP1)是唾液中多种分子之一,但它的功能仍有待确定。糖尿病(DM)的金标准诊断方法是检查血浆或血清中的葡萄糖或 HbA1C 水平。本研究旨在探讨唾液 CSP1 浓度是否可作为 DM 诊断的替代指标。

方法

通过 Western blot(WB)和免疫组织化学检测重组人 CSP1(rhCSP1)单克隆抗体(mAbs)的质量。用合格的捕获和检测 mAbs 制备夹心 ELISA,用于测量唾液中的 CSP1 水平。通过夹心 ELISA 测量健康成年人和 DM 患者的 CSP1 水平,并通过 Student's t 检验对其结果进行统计学分析。绘制受试者工作特征(ROC)曲线并计算曲线下面积(AUC)。

结果

检测到的 mAbs 在 WB 中识别出 27kDa 的唾液 CSP1,在免疫组织化学中仅染色唾液腺。OD450nm 值与标准曲线之间的 Pearson 相关系数显示出良好的线性关系(r2 = 0.995)。夹心 ELISA 法测定的 10 名健康成年人和 18 名 DM 患者唾液 CSP1 的中位数(25%至 75%)分别为 3.92µg/mL(3.15-4.02)和 4.35µg/mL(3.94-5.11)。两组间 CSP1 水平差异有统计学意义(p=0.026)。CSP1 的灵敏度为 64.71%,特异性为 88.89%,AUC 为 0.784(p=0.003)。这些结果表明,所构建的夹心 ELISA 是一种区分 DM 患者和健康个体的良好诊断检测工具。

结论

本研究数据显示,DM 患者的 CSP1 水平与对照组相比显著升高,表明唾液中的 CSP1 水平可作为 DM 患者检测或筛查的潜在生物标志物。然而,还需要进一步的研究来提供科学和临床验证。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验