Abstract

The influence of lead selection on QT estimation in the 12-lead electrocardiogram was assessed in 63 patients (21 control subjects, 21 with anterior myocardial infarction, 21 with inferior myocardial infarction). QT estimates varied between leads. The variation was greater in patients with myocardial infarction than in control subjects (mean dispersion of QT: control subjects, 48 +/- 18 ms [+/- standard deviation]; anterior myocardial infarction, 70 +/- 30 ms; inferior myocardial infarction, 73 +/-32 ms). The maximum QT in any lead (QTmax) was determined and the deviation of each lead from this maximum value calculated. In all 3 groups, anteroseptal leads (V2 or V3) provided the closest approximation to QTmax. Interlead variability was found to be mainly due to variation in timing of the end of the T wave, rather than the onset of the QRS complex. The variability due to leads was considerably greater than the variability due to cycles, observers or measurement error. Implementation of a variety of current lead selection practices resulted in widely divergent estimates of QT interval. It is concluded that there is a need for standardization of lead selection practice for QT measurement. If measurements are confined to one or a few leads, anteroseptal leads provide the closest approximation to QTmax.

摘要

在63例患者(21例对照者、21例前壁心肌梗死患者、21例下壁心肌梗死患者)中评估了导联选择对12导联心电图QT间期估算的影响。QT估算值在不同导联之间存在差异。心肌梗死患者的这种差异大于对照者(QT的平均离散度:对照者为48±18毫秒[±标准差];前壁心肌梗死患者为70±30毫秒;下壁心肌梗死患者为73±32毫秒)。确定了任一导联中的最大QT(QTmax),并计算了各导联与该最大值的偏差。在所有3组中,前间隔导联(V2或V3)最接近QTmax。发现导联间变异性主要归因于T波终点时间的变化,而非QRS波群的起始。导联引起的变异性远大于心动周期、观察者或测量误差引起的变异性。实施多种当前的导联选择方法会导致QT间期估算值差异很大。得出的结论是,需要对QT测量的导联选择方法进行标准化。如果测量限于一个或几个导联,前间隔导联最接近QTmax。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验