Department of Gastroenterology.
Department of Internal Medicine, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.
Medicine (Baltimore). 2020 Dec 18;99(51):e23685. doi: 10.1097/MD.0000000000023685.
Because of endoscopist fatigue, the time of colonoscopy have been shown to influence adenoma detection rate (ADR). Computer-aided detection (CADe) provides simultaneous visual alerts on polyps during colonoscopy and thus to increase adenoma detection rate. This is attributable to the strengthening of endoscopists diagnostic level and alleviation of fatigue. The aim of the study was to investigate whether CADe colonoscopy could eliminate the influence of the afternoon fatigue on ADR.We retrospectively analyzed the recorded data of patients who were performed CADe colonoscopy from September 2017 to February 2019 in Endoscopy Center of Sichuan Provincial People's Hospital. Patients demographic as well as baseline data recorded during colonoscopy were used for the analysis. Morning colonoscopy was defined as colonoscopic procedures starting between 8:00 am and 12:00 noon. Afternoon colonoscopy was defined as procedures starting at 2:00 pm and thereafter. The primary outcome was ADR. Univariate analysis and multivariate regression analysis were also performed.A total of 484 CADe colonoscopies were performed by 4 endoscopists in the study. The overall polyp detection rate was 52% and overall ADR was 35.5%. The mean number of adenomas detected per colonoscopy (0.62 vs 0.61, P > .05) and ADR (0.36 vs 0.35, P > .05) were similar in the am and pm group. Multivariable analysis shows that the ADR of CADe colonoscopy was influenced by the age (P < .001), gender (P = .004) and withdrawal time (P < .001), no correlation was found regarding bowel preparation (P = .993) and endoscopist experience (P = .804).CADe colonoscopy could eliminate the influence of the afternoon fatigue on ADR. The ADR during CADe colonoscopy is significantly affected by age, gender and withdrawal time.
由于内镜医师疲劳,结肠镜检查时间已被证明会影响腺瘤检出率(ADR)。计算机辅助检测(CADe)可在结肠镜检查期间对息肉进行同步视觉报警,从而提高腺瘤检出率。这归因于增强了内镜医师的诊断水平和缓解了疲劳。本研究旨在探讨 CADe 结肠镜检查是否可以消除下午疲劳对 ADR 的影响。
我们回顾性分析了 2017 年 9 月至 2019 年 2 月在四川省人民医院内镜中心行 CADe 结肠镜检查的患者的记录数据。分析了患者的人口统计学资料以及结肠镜检查期间记录的基线资料。上午结肠镜检查定义为 8:00 am 至 12:00 noon 之间进行的结肠镜检查。下午结肠镜检查定义为下午 2:00 以后进行的结肠镜检查。主要结局是 ADR。还进行了单变量分析和多变量回归分析。
本研究共进行了 484 例 CADe 结肠镜检查,由 4 名内镜医师完成。总体息肉检出率为 52%,总体 ADR 为 35.5%。每例结肠镜检查检出的腺瘤平均数量(0.62 比 0.61,P>.05)和 ADR(0.36 比 0.35,P>.05)在上午和下午组之间相似。多变量分析显示,CADe 结肠镜检查的 ADR 受年龄(P<.001)、性别(P=0.004)和退出时间(P<.001)的影响,与肠道准备(P=0.993)和内镜医师经验(P=0.804)无关。
CADe 结肠镜检查可以消除下午疲劳对 ADR 的影响。CADe 结肠镜检查的 ADR 受年龄、性别和退出时间的显著影响。