Boscato L M, Stuart M C
Garvan Institute of Medical Research, St. Vincent's Hospital, Sydney, NSW, Australia.
Clin Chem. 1988 Jan;34(1):27-33.
We verified that antibody-binding substances in serum that interfere in two-site immunoassays involving murine antibodies are heterophilic antibodies. Incubation of serum containing heterophilic antibodies and a murine monoclonal antibody to human choriogonadotropin (hCG) leads to formation of a series of soluble immune complexes. We investigated the recognition of hCG by reagent antibody in the presence of heterophilic antibodies and found this recognition to be diminished. Consequently, about 30% of serum samples containing heterophilic antibodies falsely appear to contain increased concentrations of hCG. The effect on analyte recognition probably results from steric inhibition of hCG binding to complexed antibody. Heterophilic antibodies detected with a murine antibody also bound immunoglobulin from several other species but did not bind all of those tested.
我们证实,血清中干扰涉及鼠抗体的双位点免疫测定的抗体结合物质是嗜异性抗体。含有嗜异性抗体的血清与抗人绒毛膜促性腺激素(hCG)的鼠单克隆抗体孵育会导致形成一系列可溶性免疫复合物。我们研究了在嗜异性抗体存在下试剂抗体对hCG的识别,发现这种识别能力降低。因此,约30%含有嗜异性抗体的血清样本会错误地显示hCG浓度升高。对分析物识别的影响可能是由于hCG与复合抗体结合的空间位阻抑制所致。用鼠抗体检测到的嗜异性抗体也能与其他几种物种的免疫球蛋白结合,但并非与所有测试的免疫球蛋白都能结合。