Kubín V, Jelínková J, Franêk J
Zentralbl Bakteriol Orig A. 1977 Jul;238(3):330-5.
The method of counter-immunoelectrophoresis (CIE) was tested for its applicability to group B streptococcus typing. The results obtained were compared with the typing by the ring precipitin test. Identical antigens and identical hyperimmune typing serum batches had been used in both methods. A large majority of 75 freshly isolated strains were typed identically by both methods. Five strains with a weak antigenic outfit were untypable by the ring precipitin test but were typed by CIE owing to a higher sensitivity of CIE method. Two strains were typable by the precipitin test but not by CIE; an explanation for this phenomenon is lacking. The CIE method in group B typing is specific, rapid, highly sensitive and relatively simple. It requires strict maintenance of standard conditions. The method is economical with respect to manipulation and material, requires small amounts of diagnostic antisera. Potent antisera may be used diluted. Moreover, sera for CIE typing need not be absorbed to remove group B antibodies. CIE method is practicable for group B streptococcus typing, especially in laboratories carrying out routine large scale type identification.
对对流免疫电泳(CIE)方法用于B组链球菌分型的适用性进行了测试。将获得的结果与环状沉淀试验的分型结果进行比较。两种方法均使用了相同的抗原和相同批次的超免疫分型血清。75株新鲜分离的菌株中,绝大多数通过两种方法得到的分型结果相同。5株抗原性较弱的菌株无法通过环状沉淀试验分型,但由于CIE方法具有更高的灵敏度,可通过CIE分型。有2株菌株可通过沉淀试验分型,但不能通过CIE分型;目前尚缺乏对此现象的解释。CIE方法用于B组分型具有特异性、快速、高度灵敏且相对简单的特点。它需要严格维持标准条件。该方法在操作和材料方面较为经济,所需诊断抗血清量少。高效价抗血清可稀释使用。此外,用于CIE分型的血清无需吸收以去除B组抗体。CIE方法适用于B组链球菌分型,尤其适用于进行常规大规模分型鉴定的实验室。