Suppr超能文献

子宫癌自动细胞筛选的基础研究。IV. CYBEST的样本要求及细胞分散模拟试验

Fundamental study of automatic cytoscreening for uterine cancer. IV. Sample requirements for CYBEST and simulation test of cell dispersion.

作者信息

Tanaka N, Ikeda H, Ueno T, Watanabe S, Imasato Y, Tsunekawa S

出版信息

Acta Cytol. 1977 Jul-Aug;21(4):531-5.

PMID:333840
Abstract

The preparation of samples with good cell dispersion and without cell overlapping is a particularly important problem, whether for image processing systems or for flow systems. Simulation tests were carried out to estimate a cell density with good cell dispersion and a minimum number of overlapping cells. A little less than 50 cells per mm2 was disclosed to show a condition of sufficient cell dispersion. By microscopical observation and counting of the malignant cells using ten cases of uterine cervical carcinoma, it was found that in most instances over 50 malignant cells were contained in 20,000 to 40,000 cells on the smears. When the cell density is approximately 50 per mm2, the scanning area of the CYBEST of 40 X 20 mm may contain up to 40,000 cells. The probability that such a number of cells contains malignant cells is extremely high, in fact, nearly 100 per cent. By field tests, it was experimentally confirmed that these cell densities are very adequate for the function of the CYBEST.

摘要

对于图像处理系统或流动系统而言,制备具有良好细胞分散性且无细胞重叠的样本是一个尤为重要的问题。进行了模拟测试以估算具有良好细胞分散性且重叠细胞数量最少的细胞密度。结果显示,每平方毫米略少于50个细胞时呈现出足够的细胞分散状态。通过对10例子宫颈癌病例的恶性细胞进行显微镜观察和计数,发现涂片上20000至40000个细胞中,大多数情况下含有超过50个恶性细胞。当细胞密度约为每平方毫米50个时,40×20毫米的CYBEST扫描区域可能包含多达40000个细胞。如此数量的细胞含有恶性细胞的概率极高,实际上几乎为100%。通过现场测试,实验证实这些细胞密度对于CYBEST的功能非常合适。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验