Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan.
Department of Internal Medicine, Fukuyama City Hospital, Fukuyama, Japan.
J Infect Chemother. 2021 May;27(5):751-754. doi: 10.1016/j.jiac.2020.12.010. Epub 2021 Jan 2.
Herein, we report the case of a 74-year-old man diagnosed with Legionella pneumonia detected by Loop-Mediated Isothermal Amplification (LAMP) method, which was suspected to have been transmitted from the potting soil. Legionella longbeachae was identified in the sputum culture. The patient was intubated and maintained on mechanical ventilation. Antimicrobial therapy with azithromycin was also administered. His symptoms were resolved and he was discharged after 26 days of hospitalization. Legionella longbeachae pneumonia rarely occurs in Japan, and published literature of Legionella longbeachae pneumonia cases in Japan was reviewed. Patients with severe pneumonia exposed to potting soils, but with negative urinary antigen test results, should be examined by LAMP method.
在此,我们报告了一例通过环介导等温扩增(LAMP)方法检测出的军团菌肺炎病例,该病例疑似由盆栽土传播。痰培养中鉴定出嗜肺军团菌。患者进行了气管插管并接受机械通气。同时给予阿奇霉素进行抗菌治疗。经过 26 天的住院治疗,他的症状得到缓解并出院。嗜肺军团菌肺炎在日本很少见,我们还对日本嗜肺军团菌肺炎病例的文献进行了回顾。对于暴露于盆栽土但尿抗原检测结果为阴性的严重肺炎患者,应通过 LAMP 方法进行检查。