Refractive precision in uncomplicated eyes with pseudoexfoliation: three-piece versus one-piece intraocular lens implantation.

作者信息

Onur Ismail Umut, Kırık Furkan, Yiğit Fadime Ulviye, Vural Asli Deger, Cavusoglu Ercan, Evcimen Yusuf

机构信息

Department of Ophthalmology, Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Istanbul, Turkey.

出版信息

Acta Ophthalmol. 2021 Sep;99(6):616-620. doi: 10.1111/aos.14703. Epub 2021 Jan 7.

Abstract

PURPOSE

To evaluate the refractive precision of three-piece versus one-piece intraocular lenses (IOLs) in eyes with pseudoexfoliation (PXF) and changes in anterior chamber depth (ACD) following cataract surgery.

METHODS

This prospective, nonrandomized, interventional, comparative case series included PXF eyes, which were implanted with one-piece acrylic IOL or three-piece acrylic IOLs (Group A; n = 31, Group B; n = 30). Non-PXF control eyes were implanted with one-piece acrylic IOL (Group C; n = 30). Postoperative refractive error (RE) and absolute RE, as well as pre- to postoperative ACD changes, were statistically analysed. A p value < 0.05 was considered statistically significant.

RESULTS

Changes in ACD (mean ± standard deviation) in Groups A, B and C were 0.9 ± 0.4, 1.0 ± 0.3 and 0.7 ± 0.4 mm, respectively. Significant differences were found between Groups A and C (p = 0.043) and between Groups B and C (p = 0.008). In Groups A, B and C, the median and interquartile (Q1 to Q3) values were 0.3 (-0.8 to 1.0), -0.5 (-0.8 to -0.3) and 0.1 (-0.4 to 0.3) for RE and 1.0 (0.4 to 1.3), 0.5 (0.3 to 0.8) and 0.3 (0.3 to 0.5) for absolute RE, respectively. The RE differences between Group A and B (p = 0.009) and Group B and C (p < 0.001) were statistically significant. For absolute RE, the differences were significant for all comparisons (p < 0.05).

CONCLUSION

Refractive precision in PXF eyes may be better with three-piece than with one-piece IOL implantation, but worse than with one-piece IOL implantation in non-PXF eyes. Significant changes in ACD in PXF eyes may be related to RE.

摘要

目的

评估三件式与一体式人工晶状体(IOL)在假性剥脱(PXF)眼中的屈光精度以及白内障手术后前房深度(ACD)的变化。

方法

这项前瞻性、非随机、干预性、比较性病例系列研究纳入了植入一体式丙烯酸IOL或三件式丙烯酸IOL的PXF眼(A组;n = 31,B组;n = 30)。非PXF对照眼植入一体式丙烯酸IOL(C组;n = 30)。对术后屈光不正(RE)和绝对RE以及术前至术后ACD的变化进行了统计学分析。p值<0.05被认为具有统计学意义。

结果

A组、B组和C组的ACD变化(平均值±标准差)分别为0.9±0.4、1.0±0.3和0.7±0.4mm。A组与C组之间(p = 0.043)以及B组与C组之间(p = 0.008)存在显著差异。在A组、B组和C组中,RE的中位数和四分位数间距(Q1至Q3)值分别为0.3(-0.8至1.0)、-0.5(-0.8至-0.3)和0.1(-0.4至0.3),绝对RE分别为1.0(0.4至1.3)、0.5(0.3至0.8)和0.3(0.3至0.5)。A组与B组之间(p = 0.009)以及B组与C组之间(p < 0.001)的RE差异具有统计学意义。对于绝对RE,所有比较的差异均具有统计学意义(p < 0.05)。

结论

在PXF眼中,三件式IOL植入的屈光精度可能优于一体式IOL,但比非PXF眼中的一体式IOL植入差。PXF眼中ACD的显著变化可能与RE有关。