A method is described for simultaneously determining retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in 0.25 mL of plasma. Plasma mixed with sodium dodecyl sulfate is deproteinized with ethanol containing tocopherol acetate, then extracted with heptane. The evaporated organic layer is reconstituted with mobile phase (methanol/acetonitrile/chloroform, 47/47/6 by vol) and injected onto a 100 x 4.6 mm 3-micron column of Spherisorb ODS-2 (LKB) at 1.5 mL/min. The alpha- and beta-carotenes are well resolved during the 6.5-min run. Retinol is monitored at 325 nm, the tocopherols at 292 nm, and the carotenoids at 450 nm. Extraction of concentrations as great as 135 mumol/L is complete. Intrabatch CVs were 1.7%, 2.3%, 4.1%, 10.4%, 6.4%, and 3.6% for retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin, respectively. Interbatch CVs for measurements on 30 occasions over 11 weeks were about 10% for all components except alpha-tocopherol (5.3%). Results agree well with those for retinol, alpha-tocopherol, and beta-carotene in quality-control samples.
本文描述了一种可同时测定0.25 mL血浆中视黄醇、α-生育酚、β-胡萝卜素、α-胡萝卜素、番茄红素和β-隐黄质的方法。将血浆与十二烷基硫酸钠混合,用含乙酸生育酚的乙醇进行脱蛋白处理,然后用庚烷萃取。蒸发后的有机层用流动相(甲醇/乙腈/氯仿,体积比为47/47/6)复溶,并以1.5 mL/min的流速注入100×4.6 mm、3微米的Spherisorb ODS-2(LKB)柱中。在6.5分钟的运行过程中,α-和β-胡萝卜素能得到很好的分离。在325 nm处监测视黄醇,在292 nm处监测生育酚,在450 nm处监测类胡萝卜素。浓度高达135 μmol/L的萃取过程完整。批内变异系数(CV)对视黄醇、α-生育酚、β-胡萝卜素、α-胡萝卜素、番茄红素和β-隐黄质分别为1.7%、2.3%、4.1%、10.4%、6.4%和3.6%。在11周内进行30次测量的批间CV,除α-生育酚为5.3%外,所有组分约为10%。结果与质量控制样品中视黄醇、α-生育酚和β-胡萝卜素的结果非常吻合。