Abstract

This study aimed at the assessment of the impact of various culinary processes on the fate of chromium (Cr) species (Cr(III) and Cr(VI)) in infant formula milk, semi-skimmed milk and bovine meat samples. The cooking procedures were boiling at 70°C/100°C (milk samples) and frying without and with oil (95°C and 120°C) (bovine meat). The levels of Cr(III) and Cr(VI) in raw and cooked samples were determined by high-performance liquid chromatography (HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) using double spike species-specific-isotope dilution (SS-ID). The species were extracted by sequential complexation of Cr(III) with ethylenediaminetetraacetic acid and of Cr(VI) with 1,5-diphenylcarbazide in the same analytical run by heating at 70°C for 50 min. Anion exchange chromatography using a Dionex IonPac™ AG7 column and a mobile phase consisting of 10 mM HNO, 2.5% MeOH and 30 mM EDTA at pH 2 was employed for species separation. The quantification limits were 0.013 and 0.049 µg kg for Cr(III) and Cr(VI), respectively. ANOVA test used to compare the mean Cr species concentrations showed no significant differences between raw and cooked samples. The results obtained in the present study show that oxidation of Cr(III) to Cr(VI) does not occur during thermal cooking of milk and bovine meat samples. A selection of 10 samples of each type were analysed in terms of total Cr (Cr) as well as speciation (Cr(III) and Cr(VI)). Cr(VI) was not quantified in any of these samples, whereas Cr(III) levels ranged from 0.22 (infant formula milk) up to 80 µg kg (chorizo sausage). Additionally, Cr(III) and Cr levels were comparable hence demonstrating that in the samples analysed in this study, Cr is found exclusively as Cr(III) species.

摘要

本研究旨在评估各种烹饪过程对婴儿配方奶粉、半脱脂牛奶和牛肉样品中铬(Cr)形态(Cr(III)和 Cr(VI))命运的影响。烹饪程序包括在 70°C/100°C(牛奶样品)下煮沸和无油及加油(95°C 和 120°C)下油炸(牛肉)。使用高效液相色谱(HPLC)与电感耦合等离子体质谱(ICP-MS)联用,通过双尖峰物种特异性同位素稀释(SS-ID)测定生样和熟样中 Cr(III)和 Cr(VI)的水平。通过在 70°C 下加热 50 分钟,使 Cr(III)与乙二胺四乙酸络合,Cr(VI)与 1,5-二苯卡巴肼络合,在同一分析运行中同时提取两种形态。使用 Dionex IonPac™ AG7 柱和包含 10 mM HNO、2.5% MeOH 和 30 mM EDTA 的流动相(pH 值 2)进行阴离子交换色谱法对形态进行分离。Cr(III)和 Cr(VI)的定量限分别为 0.013 和 0.049 µg kg。用于比较生样和熟样中 Cr 形态浓度均值的方差分析(ANOVA)检验未显示出差异有统计学意义。本研究结果表明,Cr(III)在牛奶和牛肉样品的热烹饪过程中不会被氧化为 Cr(VI)。对每种类型的 10 个样品进行了总 Cr(Cr)和形态(Cr(III)和 Cr(VI))分析。在这些样品中均未定量 Cr(VI),而 Cr(III)水平范围为 0.22(婴儿配方奶粉)至 80 µg kg(chorizo 香肠)。此外,Cr(III)和 Cr 水平相当,因此表明在本研究分析的样品中,Cr 仅以 Cr(III)形态存在。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验