Han Xiaoyan, Fan Qi, Hua Zhixiang, Qiu Xiaodi, Qian Dongjin, Yang Jin
Eye Institute and Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital, Fudan University, 200031, Shanghai, China.
The Key Laboratory of Myopia, Ministry of Health, 200031, Shanghai, China.
BMC Ophthalmol. 2021 Jan 13;21(1):34. doi: 10.1186/s12886-020-01794-2.
To investigate the distribution of corneal astigmatism, aberration, and biometric parameters in Chinese congenital cataract (CC) /developmental cataract patients before cataract surgery.
We evaluated eyes of CC /developmental cataract patients scheduled for cataract surgery from January 2016 to September 2019. Astigmatism, aberrations, and biometric parameters were measured with the Pentacam Scheimpflug imaging device (Pentacam HR, Oculus). Cataract was diagnosed and classified by slit-lamp examination after full mydriasis.
We evaluated 538 eyes in 356 patients. The mean values of anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), and total corneal astigmatism (TCA) were determined as 1.98 ± 1.06 D (range 0.0‒4.8 D), 0.49 ± 0.26 D (range 0.0‒1.9 D), and 2.09 ± 1.19 D (range 0.2‒8.8 D), respectively. ACA and TCA ≥ 1.25 D was present in 379 eyes (70.3%) and 392 eyes (72.8%), respectively. PCA between 0.25 D and 0.75 D was found in 380 eyes (70.6%). There was a statistically significant positive linear correlation between lower-order aberrations root mean square values (LOA RMS) and corneal astigmatism (CA). Furthermore, in terms of distribution of central cornea thickness, anterior chamber depth, ACA, PCA, and TCA in different types of cataracts, ACA was highest in patients with zonular cataracts. Finally, we found anterior corneal measurements may overestimate WTR astigmatism, underestimate ATR astigmatism, and underestimate oblique astigmatism, respectively.
Most CC /developmental cataract patients had moderate to high astigmatism and ACA accounted for the largest proportion in the zonular group. This can provide a basis for planning of CC/developmental cataract surgery by ophthalmologists in clinical practice.
研究中国先天性白内障(CC)/发育性白内障患者白内障手术前角膜散光、像差及生物测量参数的分布情况。
我们评估了2016年1月至2019年9月计划行白内障手术的CC/发育性白内障患者的眼睛。使用Pentacam Scheimpflug成像设备(Pentacam HR,Oculus)测量散光、像差及生物测量参数。充分散瞳后通过裂隙灯检查诊断并分类白内障。
我们评估了356例患者的538只眼睛。前角膜散光(ACA)、后角膜散光(PCA)和总角膜散光(TCA)的平均值分别确定为1.98±1.06 D(范围0.0-4.8 D)、0.49±0.26 D(范围0.0-1.9 D)和2.09±1.19 D(范围0.2-8.8 D)。ACA和TCA≥1.25 D分别出现在379只眼睛(70.3%)和392只眼睛(72.8%)中。380只眼睛(70.6%)的PCA在0.25 D至0.75 D之间。低阶像差均方根值(LOA RMS)与角膜散光(CA)之间存在统计学显著的正线性相关性。此外,就不同类型白内障的中央角膜厚度、前房深度、ACA、PCA和TCA的分布而言,带状白内障患者的ACA最高。最后,我们发现前角膜测量可能分别高估顺规散光、低估逆规散光和低估斜向散光。
大多数CC/发育性白内障患者有中度至高散光,且ACA在带状组中占比最大。这可为临床眼科医生规划CC/发育性白内障手术提供依据。