Abstract

PURPOSE

The simplified reference tissue model (SRTM) is commonly applied for the quantification of brain positron emission tomography (PET) studies, particularly because it avoids arterial cannulation. SRTM requires a validated reference region which is obtained by baseline-blocking or displacement studies. Once a reference region is validated, the use should be verified for each new subject. This verification normally requires volume of distribution (V) of a reference region. However, performing dynamic scanning and arterial sampling is not always possible, specifically in elderly subjects and in advanced disease stages. The aim of this study was to investigate the use of non-invasive standardised uptake value (SUV) approaches, in comparison to V, as a verification of the previously validated grey matter cerebellum reference region for [F]flortaucipir and [F]florbetapir PET imaging in Alzheimer's disease (AD) patients and controls.

PROCEDURES

Dynamic 130-min [F]flortaucipir PET scans obtained from nineteen subjects (10 AD patients) and 90-min [F]florbetapir dynamic scans obtained from fourteen subjects (8 AD patients) were included. Regional V's were estimated for both tracers and were considered the standard verification of the previously validated reference region. Non-invasive SUVs corrected for body weight (SUV), lean body mass (SUL), and body surface area (SUV) were obtained by using later time intervals of the dynamic scans. Simulations were also performed to assess the effect of flow and specific binding (BP) on the SUVs.

RESULTS

A low SUV corresponded well with a low V for both [F]flortaucipir and [F]florbetapir. Simulation confirmed that SUVs were only slightly affected by flow changes and that increases in SUV were predominantly determined by the presence of specific binding.

CONCLUSIONS

In situations where dynamic scanning and arterial sampling is not possible, a low SUV for [F]flortaucipir and a low SUV for [F]florbetapir may be used as indication for absence of specific binding in the grey matter cerebellum reference region.

摘要

目的

简化参考组织模型(SRTM)常用于脑正电子发射断层扫描(PET)研究的定量,特别是因为它避免了动脉插管。SRTM 需要一个经过验证的参考区域,该区域通过基线阻断或置换研究获得。一旦验证了参考区域,就应该在每个新对象中进行使用验证。通常,这需要参考区域的分布容积(V)。然而,在老年人和晚期疾病阶段,动态扫描和动脉取样并不总是可行的。本研究旨在研究非侵入性标准化摄取值(SUV)方法的使用,与 V 相比,作为对先前验证的灰质小脑参考区域用于阿尔茨海默病(AD)患者和对照者[F]flortaucipir 和[F]florbetapir PET 成像的验证。

过程

纳入了 19 名受试者(10 名 AD 患者)的 130 分钟[F]flortaucipir PET 动态扫描和 14 名受试者(8 名 AD 患者)的 90 分钟[F]florbetapir 动态扫描。对两种示踪剂均进行了区域性 V 的估计,并认为这是对先前验证的参考区域的标准验证。通过使用动态扫描的后期时间间隔,获得了体重校正的非侵入性 SUV(SUV)、瘦体重校正的 SUV(SUL)和体表面积校正的 SUV(SUV)。还进行了模拟,以评估流量和特异性结合(BP)对 SUV 的影响。

结果

对于[F]flortaucipir 和[F]florbetapir,低 SUV 与低 V 对应良好。模拟证实,SUV 仅受到流量变化的轻微影响,SUV 的增加主要由特异性结合的存在决定。

结论

在无法进行动态扫描和动脉取样的情况下,对于[F]flortaucipir 和[F]florbetapir,低 SUV 可能表明灰质小脑参考区域不存在特异性结合。