Kurt Hasan Anıl, Demirci Emrah
Department of Urology, Faculty of Medical, Canakkale Onsekiz Mart University, Canakkale, Turkey.
Department of Urology, Yozgat City Hospital, Yozgat, Turkey.
J Endourol Case Rep. 2020 Dec 29;6(4):399-401. doi: 10.1089/cren.2020.0053. eCollection 2020.
Amplatz sheaths are hollow tubes that serve as the portal for the insertion of the nephroscope during percutaneous nephrolithotomy (PCNL). Breakage of this tube during the procedure is rare, but when it does occur it should be recognized and addressed promptly. A 46-year-old Caucasian male patient was scheduled for PCNL. The Amplatz sheath was inserted in the usual manner over a balloon dilator and nephroscopy was performed. Profuse bleeding was encountered early. Upon meticulous endoscopic navigation, the broken Amplatz tube was recognized and replaced. This allowed us to identify and remove the fragment of the Amplatz tube, followed by stone fragmentation and removal. Our experience highlights the importance of recognizing this rare complication of a broken Amplatz sheath that should be managed promptly and effectively through endoscopic means without the need to abort the planned PCNL.
安普茨鞘是空心管,在经皮肾镜取石术(PCNL)期间作为插入肾镜的通道。该管在手术过程中破裂很少见,但一旦发生,应及时识别并处理。一名46岁的白种男性患者计划进行PCNL。以常规方式将安普茨鞘套在球囊扩张器上插入,并进行肾镜检查。早期出现大量出血。经过仔细的内镜操作,识别出破裂的安普茨管并进行了更换。这使我们能够识别并取出安普茨管的碎片,随后进行结石破碎和取出。我们的经验强调了识别这种罕见的安普茨鞘破裂并发症的重要性,应通过内镜手段及时有效地处理,而无需中止计划好的PCNL。