Laboratory of Biomimetic Nanomaterials, Department of Orthodontics, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China.
Department of General Dentistry, University of Rochester Eastman Institute for Oral Health Rochester, Rochester, NY, USA.
J Int Med Res. 2021 Jan;49(1):300060520982708. doi: 10.1177/0300060520982708.
To evaluate the accuracy, reliability, and efficiency of voxel- and surface-based registrations for cone-beam computed tomography (CBCT) mandibular superimposition in adult orthodontic patients.
Pre- and post-orthodontic treatment CBCT scans of 27 adult patients were obtained. Voxel- and surface-based CBCT mandibular superimpositions were performed using the mandibular basal bone as a reference. The accuracy of the two methods was evaluated using the absolute mean distance measured. The time that was required to perform the measurements using these methods was also compared. Statistical differences were determined using paired -tests, and inter-observer reliability was assessed by intraclass correlation coefficients (ICCs).
The absolute mean distance on seven mandible surface areas between voxel- and surface-based registrations was similar but not significantly different. ICC values of the surface-based registration were 0.918 to 0.990, which were slightly lower than those of voxel-based registration that ranged from 0.984 to 0.996. The time required for voxel-based registration and surface-based registration was 44.6 ± 2.5 s and 252.3 ± 7.1 s, respectively.
Both methods are accurate and reliable and not significantly different from each other. However, voxel-based registration is more efficient than surface-based registration for CBCT mandibular superimposition.
评估基于体素和基于表面的锥形束计算机断层扫描(CBCT)下颌骨叠加在成人正畸患者中的准确性、可靠性和效率。
获取 27 例成人正畸治疗前后的 CBCT 扫描。使用下颌骨基底部作为参考,分别进行基于体素和基于表面的 CBCT 下颌骨叠加。使用测量的绝对平均距离评估两种方法的准确性。还比较了使用这些方法进行测量所需的时间。使用配对 t 检验确定统计学差异,并使用组内相关系数(ICC)评估观察者间可靠性。
体素和基于表面的注册之间的七个下颌骨表面区域之间的绝对平均距离相似,但无统计学差异。基于表面的注册的 ICC 值为 0.918 至 0.990,略低于基于体素的注册,范围从 0.984 至 0.996。基于体素的注册和基于表面的注册所需的时间分别为 44.6±2.5 s 和 252.3±7.1 s。
两种方法均准确可靠,且彼此之间无显著差异。然而,对于 CBCT 下颌骨叠加,基于体素的注册比基于表面的注册更有效率。