Department of Radiology, Selcuk University School of Medicine, Konya, Turkey.
Ahi Evran University School of Medicine, Department of Radiology, Kırsehir, Turkey.
Acta Radiol. 2022 Jan;63(1):93-99. doi: 10.1177/0284185120983279. Epub 2021 Jan 21.
Changes in optic nerve vascularity are observed in many diseases. Superb microvascular imaging (SMI) has the potential to become the method of choice for detecting microvasculature in the optic nerves.
To evaluate optic nerve vascularity in healthy individuals through power Doppler sonography (PDUS) and SMI.
Twenty-seven healthy patients with 54 eyes were prospectively evaluated. The duration of the examination for optic nerve vascularity lasted until the posterior ciliary artery blood supply was observed in PDUS and SMI. The visibility of vascularity, as well as the ratio of the vascular structures to the optic nerves (vascular index [VI]), was evaluated.
Fifty-four eyes were evaluated from a total of 27 patients (mean age = 49.0 ± 19.42 years). The VI value for the right optic nerve was 29.58 ± 4.00 while for the left optic nerve, it was 31.21 ± 3.52. Vascularity was clearly observed in both eyes (n = 54) in all 27 cases in the evaluation performed with the SMI technique. However, with the power Doppler examination, vascular flow was not observed in 14 right eyes and in 10 left eyes within the specified timeframe.
The results indicate that imaging of vascular structures can be done faster and better with SMI than PDUS examination. The normal VI values may provide important information about the blood supply of the optic nerve, which is of relevance in orbital pathologies and many systemic conditions.
许多疾病都会观察到视神经血管变化。超微血流成像(SMI)有可能成为检测视神经微血管的首选方法。
通过功率多普勒超声(PDUS)和 SMI 评估健康个体的视神经血管。
前瞻性评估 27 名健康患者的 54 只眼。视神经血管检查的持续时间直至在 PDUS 和 SMI 中观察到睫状后动脉供血。评估血管结构的可视性以及与视神经的血管结构比(血管指数[VI])。
从总共 27 名患者(平均年龄 49.0±19.42 岁)评估了 54 只眼。右眼视神经的 VI 值为 29.58±4.00,左眼视神经的 VI 值为 31.21±3.52。在 SMI 技术评估的 27 例中,所有 54 只眼均清晰观察到血管(n=54)。然而,在指定时间范围内,14 只右眼和 10 只左眼的功率多普勒检查未观察到血管血流。
结果表明,与 PDUS 检查相比,SMI 可以更快、更好地进行血管结构成像。正常的 VI 值可能提供有关视神经血液供应的重要信息,这对于眼眶病变和许多系统性疾病具有重要意义。