CIRAD, UMR ISEM, Montpellier, France.
ISEM, CNRS, EPHE, IRD, Univ Montpellier, Montpellier, France.
J Fish Dis. 2021 May;44(5):505-512. doi: 10.1111/jfd.13337. Epub 2021 Jan 24.
A method combining the FTA Elute card and visual colorimetric loop-mediated isothermal amplification (FTA-e/LAMP) was tested to diagnose Streptococcus agalactiae infections in vitro and in vivo. FTA-e/LAMP consists of two main steps: first, the FTA card is used to extract DNA and then a colorimetric loop-mediated isothermal amplification (LAMP) reaction is carried out on the extracted DNA. In vitro sensitivity was 1.9 x 10 CFU/mL, and regarding specificity, all nine S. agalactiae strains tested positive. All Streptococcus spp. tested negative, except for S. dysgalactiae, thereby indicating the need for another set of primers to distinguish this species from S. agalactiae. To diagnose S. agalactiae infections using FTA-e/LAMP in vivo, two experimental trials on juvenile Oreochromis niloticus infected with bovine or piscine strains were carried out. Sensitivity in symptomatic fish was 100%, and 50.7% of fish without signs were positive. All negative control fish tested negative (n = 28). No bacteria were detected after 16 days post-infection (dpi). Accuracy during the first week (1-7 dpi) was 89% and decreased to 44% thereafter (10-22 dpi). FTA-e/LAMP results suggest that this method is a promising tool for early and fast diagnosis of S. agalactiae on tilapia farms.
一种结合 FTA Elute 卡和目视比色环介导等温扩增(FTA-e/LAMP)的方法被用于体外和体内诊断无乳链球菌感染。FTA-e/LAMP 由两个主要步骤组成:首先,FTA 卡用于提取 DNA,然后对提取的 DNA 进行比色环介导等温扩增(LAMP)反应。体外灵敏度为 1.9×10^CFU/mL,关于特异性,所有测试的 9 株无乳链球菌菌株均为阳性。除了 S. dysgalactiae 外,所有测试的链球菌均为阴性,这表明需要另一组引物来区分该物种与无乳链球菌。为了使用 FTA-e/LAMP 进行体内诊断无乳链球菌感染,对感染牛源或鱼源菌株的幼年奥利亚罗非鱼进行了两项实验。在有症状的鱼中,灵敏度为 100%,50.7%无症状的鱼为阳性。所有阴性对照鱼均为阴性(n=28)。感染后 16 天(dpi)后未检测到细菌。第一周(1-7 dpi)的准确率为 89%,此后降至 44%(10-22 dpi)。FTA-e/LAMP 的结果表明,该方法是在罗非鱼养殖场快速早期诊断无乳链球菌的有前途的工具。