颈动脉壁成像的 3D_T2_FFE:序列参数优化及与 3D_T2_SPACE 的比较。

Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE.

机构信息

MR Department of Affiliated Zhongshan Hospital of Sun Yat-sen University, Sun Wendong Road No. 2, Zhongshan, Guangdong, China.

出版信息

Sci Rep. 2021 Jan 26;11(1):2255. doi: 10.1038/s41598-021-81309-1.

Abstract

Similar to sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE), T2-weighted fast field echo (FFE) also has a black blood effect and a high imaging efficiency. The purpose of this study was to optimize 3D_T2_FFE and compare it with 3D_T2_SPACE for carotid imaging. The scanning parameter of 3D_T2_FFE was optimized for the imaging of the carotid wall. Twenty healthy volunteers and 10 patients with carotid plaque underwent cervical 3D_T2_FFE and 3D_T2_SPACE examinations. The signal-to-noise ratios of the carotid wall (SNR) and lumen (SNR), and the contrast-to-noise ratios between the wall and lumen (CNR) were compared. The incidence of the residual flow signal at the carotid bifurcation and the grades of flow voids in the cerebellopontine angle region in the two sequences were also compared. The reproducibility of the two sequences was tested. No significant difference was observed between the two sequences in terms of the SNR of healthy individuals and patients (P = 0.132 and 0.102, respectively). The SNR in the 3D_T2_FFE images was lower than that in the 3D_T2_SPACE images. No significant difference was observed between the two sequences in terms of the CNR. The incidence of the residual flow signal at the carotid bifurcation in 3D_T2_FFE was significantly lower than that in 3D_T2_SPACE. The grades of flow suppression in the cerebellopontine angle region in 3D_T2_SPACE was lower than that in 3D_T2_FFE. Both sequences showed excellent inter-and intra-observer reproducibility. Compared to 3D_T2_SPACE, 3D_T2_FFE showed stronger flow suppression while maintaining good imaging quality, which can be used as an alternative tool for carotid imaging.

摘要

类似于应用优化对比使用不同翻转角演化(SPACE)的采样完美,T2 加权快速场回波(FFE)也具有黑血效应和高成像效率。本研究旨在优化 3D_T2_FFE 并将其与 3D_T2_SPACE 进行比较,用于颈动脉成像。优化了 3D_T2_FFE 的扫描参数,用于颈动脉壁成像。20 名健康志愿者和 10 名颈动脉斑块患者接受了颈部 3D_T2_FFE 和 3D_T2_SPACE 检查。比较了颈动脉壁(SNR)和管腔(SNR)的信噪比,以及壁与管腔之间的对比噪声比(CNR)。比较了两种序列在颈动脉分叉处残留流信号的发生率和小脑脑桥角区域的流空等级。测试了两种序列的可重复性。两种序列在健康个体和患者的 SNR 方面无显著差异(P 值分别为 0.132 和 0.102)。3D_T2_FFE 图像的 SNR 低于 3D_T2_SPACE 图像。两种序列的 CNR 无显著差异。3D_T2_FFE 中颈动脉分叉处残留流信号的发生率明显低于 3D_T2_SPACE。3D_T2_SPACE 中小脑脑桥角区域的血流抑制等级低于 3D_T2_FFE。两种序列均表现出良好的观察者内和观察者间可重复性。与 3D_T2_SPACE 相比,3D_T2_FFE 显示出更强的血流抑制作用,同时保持良好的成像质量,可作为颈动脉成像的替代工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1d24/7838159/49637163be4e/41598_2021_81309_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验