Nakano Shinichiro, Iida Masaharu, Hasegawa Yumi, Hiraoka Takahiro, Oshika Tetsuro
Division of Ophthalmology, Ryugasaki Saiseikai Hospital, Ibaraki, Japan.
Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Jpn J Ophthalmol. 2021 Mar;65(2):288-294. doi: 10.1007/s10384-021-00812-0. Epub 2021 Jan 28.
To assess whether the outcomes of toric intraocular lens (IOL) implantation in eyes with oblique astigmatism can be improved by direct measurements of posterior corneal astigmatism using anterior segment optical coherence tomography (AS-OCT) instead of by using anterior corneal measurements alone.
Retrospective case series.
Two toric IOL power calculation methods were compared: anterior corneal astigmatism was used in the keratometry group, whilst total corneal astigmatism determined by ray tracing through the measured anterior and posterior corneal surfaces was used in the AS-OCT group. In a total of 279 eyes of 232 patients, subgroup analysis was conducted for with-the-rule (WTR) (85 eyes in the keratometry group and 34 eyes in the AS-OCT group), against-the-rule (ATR) (73/29 eyes), and oblique (26/32 eyes) astigmatism.
In the WTR and ATR astigmatism groups, the uncorrected distance visual acuity (UDVA) was significantly better in the AS-OCT group than in the keratometry group (P = 0.012 and P < 0.001, Mann-Whitney test), and the residual astigmatism was significantly smaller in the AS-OCT group than in the keratometry group (P = 0.037 and P < 0.001). In eyes with oblique astigmatism, the UDVA (P = 0.299) and residual astigmatism (P = 0.373) of the keratometry and AS-OCT groups did not differ.
Incorporation of posterior corneal astigmatism measured with AS-OCT can significantly improve the outcomes of toric IOL implantation in eyes with WTR and ATR astigmatism, but not in eyes with oblique astigmatism.
评估对于斜轴散光眼,使用眼前节光学相干断层扫描(AS - OCT)直接测量后角膜散光,而非仅使用前角膜测量,是否能改善散光人工晶状体(IOL)植入的效果。
回顾性病例系列研究。
比较两种散光IOL屈光度计算方法:角膜曲率计组使用前角膜散光,而AS - OCT组使用通过测量的前、后角膜表面光线追踪确定的总角膜散光。对232例患者的279只眼进行亚组分析,包括顺规(WTR)(角膜曲率计组85只眼,AS - OCT组34只眼)、逆规(ATR)(73/29只眼)和斜轴(26/32只眼)散光。
在WTR和ATR散光组中,AS - OCT组的未矫正远视力(UDVA)显著优于角膜曲率计组(P = 0.012和P < 0.001,Mann - Whitney检验),且AS - OCT组的残余散光显著小于角膜曲率计组(P = 0.037和P < 0.001)。在斜轴散光眼中,角膜曲率计组和AS - OCT组的UDVA(P = 0.299)和残余散光(P = 0.373)无差异。
纳入用AS - OCT测量的后角膜散光可显著改善顺规和逆规散光眼散光IOL植入的效果,但对斜轴散光眼无效。