Suppr超能文献

心率变异性和电化学皮肤电导联合用于 2 型糖尿病心血管自主神经病变的筛查和严重程度评估的可行性。

Feasibility of combining heart rate variability and electrochemical skin conductance as screening and severity evaluation of cardiovascular autonomic neuropathy in type 2 diabetes.

机构信息

Department of Neurology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.

Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.

出版信息

J Diabetes Investig. 2021 Sep;12(9):1671-1679. doi: 10.1111/jdi.13518. Epub 2021 Mar 13.

Abstract

AIMS/INTRODUCTION: Clinical studies show that either heart rate variability (HRV) or electrochemical skin conductance (ESC) alone can serve as a simple and objective method for screening cardiovascular autonomic neuropathy (CAN). We tested the hypothesis that combining these two quantitative approaches can not only reinforce accuracy in CAN screening but also provide a better estimate of CAN severity in patients with type 2 diabetes (T2DM) who had already had CAN in outpatient clinics.

MATERIALS AND METHODS

Each patient received a complete battery of cardiovascular autonomic reflex tests (CARTs), with ESC measured by SUDOSCAN, time domain of HRV measured by standard deviation of all normal RR intervals (SDNN) and frequency domain of HRV (low frequency [LF], high frequency [HF], and LF/HF ratio), and peripheral blood studies for vascular risk factors. Severity of CAN was measured by CAN score.

RESULTS

The 90 T2DM patients included 50 males and 40 females. Those with more severe CAN had lower values in feet ESC (P = 0.023) and SDNN (P < 0.0001). Multiple linear regression analysis also showed that feet ESC and SDNN value (P = 0.003 and P < 0.0001) were significantly associated with CAN score. Combining SDNN and feet ESC also can increase the diagnostic accuracy of CAN with respective to sensitivity and specificity by using receiver operating characteristic analysis.

CONCLUSIONS

Combining the results of SDNN and feet ESC can not only assess, but also quantitatively reflect the progress or improvement of autonomic nerve function (including sympathetic and parasympathetic activity) in patients with T2DM.

摘要

目的/引言:临床研究表明,心率变异性(HRV)或电化学皮肤传导(ESC)单独使用,都可以作为筛查心血管自主神经病变(CAN)的简单客观方法。我们检验了一个假设,即联合使用这两种定量方法,不仅可以提高 CAN 筛查的准确性,还可以更好地评估已经在门诊被诊断出患有 CAN 的 2 型糖尿病(T2DM)患者的 CAN 严重程度。

材料和方法

每位患者都接受了全面的心血管自主反射测试(CART),使用 SUDOSCAN 测量 ESC,标准 RR 间期标准差(SDNN)测量 HRV 的时域,频域 HRV(低频[LF]、高频[HF]和 LF/HF 比值),以及外周血血管危险因素研究。CAN 严重程度通过 CAN 评分来衡量。

结果

90 例 T2DM 患者中,有 50 名男性和 40 名女性。CAN 更严重的患者脚部 ESC(P=0.023)和 SDNN(P<0.0001)值更低。多元线性回归分析还表明,脚部 ESC 和 SDNN 值(P=0.003 和 P<0.0001)与 CAN 评分显著相关。通过接收者操作特征分析,联合使用 SDNN 和脚部 ESC 也可以提高 CAN 的诊断准确性,提高敏感度和特异度。

结论

联合使用 SDNN 和脚部 ESC 的结果,不仅可以评估,还可以定量反映 T2DM 患者自主神经功能(包括交感和副交感活动)的进展或改善。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/18bf/8409849/1b2c2b551e12/JDI-12-1671-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验