Suppr超能文献

成人周围神经超声横截面积参考值:系统评价和荟萃分析-第 I 部分:上肢神经。

Cross-sectional area reference values for peripheral nerve ultrasound in adults: a systematic review and meta-analysis-Part I: Upper extremity nerves.

机构信息

Department of Neurology, St Josef Hospital, Ruhr-University Bochum, Bochum, Germany.

Immunmediated Neuropathies Biobank (INHIBIT), Ruhr University Bochum, Bochum, Germany.

出版信息

Eur J Neurol. 2021 May;28(5):1684-1691. doi: 10.1111/ene.14759. Epub 2021 Feb 23.

Abstract

BACKGROUND AND PURPOSE

Measurement of the cross-sectional area (CSA) of peripheral nerves using ultrasound is useful in the evaluation of focal lesions like entrapment syndromes and inflammatory polyneuropathies. Here, a systematic review and meta-analysis of published CSA reference values for upper extremity nerves was performed.

METHODS

Available to date nerve ultrasound studies on healthy adults were included and a meta-analysis for CSA was provided of the following nerves: median nerve at the wrist, forearm, upper arm; ulnar nerve at the Guyon's canal, forearm, elbow, upper arm; radial nerve at the upper arm. Regression and correlation analyses for age, gender, height, weight, geographic continents and publication year are reported.

RESULTS

Seventy-four studies with 4186 healthy volunteers (mean age 42.7 years) and 18,226 examined nerve sites were included. The calculated mean pooled CSA of the median nerve at the wrist was 8.3 mm (95% confidence interval [95% CI] 7.9-8.7, n = 4071), at the forearm 6.4 mm (95% CI 5.9-6.9, n = 3021), at the upper arm 8.3 mm (95% CI 7.5-9.0, n = 1388), of the ulnar nerve at the Guyon's canal 4.1 mm (95% CI 3.6-4.6, n = 1688), at the forearm 5.2 mm (95% CI 4.8-5.7, n = 1983), at the elbow 5.9 mm (95% CI 5.4-6.5, n = 2551), at the upper arm 6.6 mm (95% CI 5.1-6.1, n = 1737) and of the radial nerve 5.1 mm (95% CI 4.0-6.2, n = 1787). Substantial heterogeneity across studies (I > 50%) was found only for the radial nerve. Subgroup analysis revealed a positive effect of age for the median nerve at the wrist and for height and weight for different sites of the ulnar nerve.

CONCLUSION

The first meta-analysis on CSA reference values for the upper extremities with no or only low heterogeneity of reported CSA values in most nerve sites is provided. Our data facilitate the goal of an international standardized evaluation protocol.

摘要

背景与目的

使用超声测量外周神经的横截面积(CSA)对于评估局灶性病变(如压迫综合征和炎性多发性神经病)非常有用。本研究对已发表的上肢神经 CSA 参考值进行了系统评价和荟萃分析。

方法

纳入了迄今为止有关健康成年人的神经超声研究,并对以下神经的 CSA 进行了荟萃分析:腕部、前臂和上臂的正中神经;Guyon 管、前臂、肘部和上臂的尺神经;上臂的桡神经。报告了年龄、性别、身高、体重、地理位置和出版年份的回归和相关性分析。

结果

纳入了 74 项研究,共 4186 名健康志愿者(平均年龄 42.7 岁)和 18226 个受检神经部位。计算得出的腕部正中神经的平均 CSA 为 8.3mm(95%置信区间[95%CI] 7.9-8.7,n=4071),前臂为 6.4mm(95%CI 5.9-6.9,n=3021),上臂为 8.3mm(95%CI 7.5-9.0,n=1388);Guyon 管的尺神经为 4.1mm(95%CI 3.6-4.6,n=1688),前臂为 5.2mm(95%CI 4.8-5.7,n=1983),肘部为 5.9mm(95%CI 5.4-6.5,n=2551),上臂为 6.6mm(95%CI 5.1-6.1,n=1737);桡神经为 5.1mm(95%CI 4.0-6.2,n=1787)。仅桡神经的研究存在明显的异质性(I>50%)。亚组分析显示,腕部正中神经的年龄、不同部位的尺神经的身高和体重对 CSA 有积极影响。

结论

本研究首次对上肢 CSA 参考值进行了荟萃分析,大多数神经部位的 CSA 值报告存在的异质性较低或无。我们的数据有助于实现国际标准化评估方案的目标。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验