Suppr超能文献

使用Bland-Altman分析法评估正中神经和尺神经超声检查中操作者的可靠性

Assessment of Operator Reliability in Ultrasound of the Median and Ulnar Nerve Using Bland-Altman Analysis.

作者信息

Philipps Jörg, Mork Hannah, Katz Maria, Knaup Mark, Beyer Kira, Spies Kristina, Corbach Johannes, Schellinger Peter D

机构信息

Department of Neurology and Neurogeriatrics, Ruhr-University Bochum, Johannes-Wesling-Klinikum Minden, UK RUB, Hans- Nolte Str. 1, D-32429 Minden, Germany.

出版信息

Diagnostics (Basel). 2021 Nov 17;11(11):2134. doi: 10.3390/diagnostics11112134.

Abstract

Currently, there is no standardized method to evaluate operator reliability in nerve ultrasound. A short prospective protocol using Bland-Altman analysis was developed to assess the level of agreement between operators with different expertise levels. A control rater without experience in nerve ultrasound, three novices after two months of training, an experienced rater with two years of experience, and a reference rater performed blinded ultrasound examinations of the left median and ulnar nerve in 42 nerve sites in healthy volunteers. The precision of Bland-Altman agreement analysis was tested using the Preiss-Fisher procedure. Intraclass correlation coefficients (ICC), coefficients of variation, and Bland-Altman limits of agreement were calculated. The sample size calculation and Preiss-Fisher procedure showed a sufficient precision of Bland-Altman agreement analysis. Limits of agreement of all trained novices ranged from 2.0 to 2.9 mm and were within the test's maximum tolerated difference. Ninety-five percent confidence intervals of limits of agreement revealed a higher precision in the experienced rater's measurements. Operator reliability in nerve ultrasound of the median and ulnar nerve arm nerves can be evaluated with a short prospective controlled protocol using Bland-Altman statistics, allowing a clear distinction between an untrained rater, trained novices after two months of training, and an experienced rater.

摘要

目前,尚无标准化方法来评估神经超声检查中操作者的可靠性。我们制定了一个采用布兰德-奥特曼分析的简短前瞻性方案,以评估不同专业水平操作者之间的一致性程度。一名没有神经超声检查经验的对照评估者、三名经过两个月培训的新手、一名有两年经验的经验丰富的评估者以及一名参考评估者,对42个健康志愿者神经部位的左侧正中神经和尺神经进行了盲法超声检查。使用普赖斯-费舍尔程序检验了布兰德-奥特曼一致性分析的精度。计算了组内相关系数(ICC)、变异系数以及布兰德-奥特曼一致性界限。样本量计算和普赖斯-费舍尔程序表明布兰德-奥特曼一致性分析具有足够的精度。所有经过培训的新手的一致性界限范围为2.0至2.9毫米,且在测试的最大容许差异范围内。一致性界限的95%置信区间显示经验丰富的评估者测量的精度更高。使用布兰德-奥特曼统计方法的简短前瞻性对照方案可以评估正中神经和尺神经臂神经超声检查中操作者的可靠性,从而能够明确区分未经培训的评估者、经过两个月培训的新手以及经验丰富的评估者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/abe2/8623197/9a8c1ea23e82/diagnostics-11-02134-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验