Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou, China.
Huadong Engineering Corporation Limited, Power Construction Corporation of China, Hangzhou, China.
Sci Total Environ. 2021 Jun 1;771:145390. doi: 10.1016/j.scitotenv.2021.145390. Epub 2021 Jan 25.
This study investigated the indoor air quality (IAQ) during humid season in an old badminton hall, to explore the IAQ characteristics of natural ventilated sports buildings for public use. The indoor air parameters (temperature, relative humidity and air velocity) and indoor air pollutants (CO, TVOC, PM and PM) were measured. A subjective approach was carried out through questionnaire survey. 185 valid questionnaires were recovered, and 68.7% of the participants had exercised. Results show that the indoor air qualities obtained through objective and subjective approaches were obviously different. Indoor PM, TVOC and CO concentrations were normal, but 37.3% of the participants complained about the building materials' smell and 73.5% of the participants reported obvious sweaty odor. Physical activity might reduce a person's sensitivity to the environment. The participants generally felt warm and hot because of the high relative humidity. Post-exercise participants felt significantly hotter than those who did not exercise, and were generally more receptive to IAQ. The method of Fanger was employed to narrow the gap between subjective and objective approaches with a modified parameter, and to furtherly estimate the ventilation. The present study demonstrates the necessity to combine two approaches together to assess the IAQ in sports buildings.
本研究调查了潮湿季节旧羽毛球馆的室内空气质量 (IAQ),旨在探索公共自然通风体育建筑的 IAQ 特征。测量了室内空气参数(温度、相对湿度和空气速度)和室内空气污染物(CO、TVOC、PM 和 PM)。通过问卷调查进行了主观评估。共回收 185 份有效问卷,其中 68.7%的参与者进行了运动。结果表明,客观和主观方法得出的室内空气质量明显不同。室内 PM、TVOC 和 CO 浓度正常,但 37.3%的参与者抱怨建筑材料的气味,73.5%的参与者报告明显的汗味。身体活动可能会降低人对环境的敏感度。由于相对湿度高,参与者普遍感到温暖和炎热。运动后的参与者比不运动的参与者感觉明显更热,并且通常对室内空气质量更敏感。本研究采用 Fanger 方法,利用修正参数缩小了主观和客观方法之间的差距,并进一步估计了通风量。本研究表明,有必要将两种方法结合起来评估体育建筑中的室内空气质量。