意大利尿液有形成分显微镜检查室间质量评价计划:20 年历程。

The Italian External Quality Assessment (EQA) program on urinary sediment by microscopy examination: a 20 years journey.

机构信息

Centre of Biomedical Research for Quality in Laboratory Medicine, University-Hospital of Padova, Padova, Italy.

Department of Laboratory Medicine, University-Hospital of Padova, Padova, Italy.

出版信息

Clin Chem Lab Med. 2020 Dec 4;59(5):845-856. doi: 10.1515/cclm-2020-1656. Print 2021 Apr 27.

Abstract

OBJECTIVES

In spite of the introduction of automated systems for urinary sediment analysis, microscopy examination remains the gold standard, and it is more than ever important to perform it with a good and reliable quality. External Quality Assessment (EQA) programs on urinary sediment are rare. The present paper provides an analysis of results from 2001 to date of the EQA Italian program which involves today 230 laboratories.

METHODS

The program includes four surveys per year. Participants are asked the identification and clinical associations of urinary sediment particles, shown as phase contrast microscopy images in the website of the Center of Biomedical Research (CRB) (2 surveys), and the diagnosis of clinical cases presented by both images and a short clinical history (2 surveys). The results of each survey are then scored and commented. In 20 years, 298 images were presented: 90 cells (9 types), 23 lipids (5 types), 87 casts (21 types), 53 crystals (14 types), 22 microorganisms (5 types), and 23 contaminants (9 types). Moreover, 27 clinical cases, covering a wide spectrum of conditions with different degrees of complexity, were presented to participants.

RESULTS

Identification: among urinary particle categories, the correct identification rate (obtained for each particle from the sum of correct + partially correct answers) was very high for micro-organisms (mean ± SD: 96.2 ± 3.5%), high for lipids (88.0 ± 11.8%) and crystals (87.0 ± 16.5%) followed, in decreasing order, by cells (82.1 ± 15.9%), casts (81.8 ± 14.8%), and contaminants (76.7 ± 22.1%). Clinical associations (n=67): the rate of correct answers was 93.5 ± 5.7% ranging from 75.0 to 100% for all but one clinical association (i.e., acute glomerulonephritis: 55.4%). Clinical cases: throughout surveys, due to the overall rate of particle misidentification, only 59.8 ± 17.1%, (range 32.5-88.7%) of participants achieved access to clinical diagnosis. Of these, 88.7 ± 10.6% (range 59.9-99.3%) were able to indicate the correct diagnosis.

CONCLUSIONS

Our program can be used as a tool to improve the identification of urine particles and the knowledge of their clinical meaning and to encourage specialists of laboratory medicine to correlate urinary findings with other laboratory data and the clinical history, an aspect that improves the value of the day by day work.

摘要

目的

尽管已经引入了用于尿液沉淀物分析的自动化系统,但显微镜检查仍然是金标准,因此进行高质量和可靠的检查比以往任何时候都更为重要。尿液沉淀物的外部质量评估 (EQA) 计划很少。本文分析了目前涉及 230 个实验室的意大利 EQA 计划从 2001 年至今的结果。

方法

该计划包括每年四次调查。参与者被要求识别和临床关联尿液沉淀物颗粒,这些颗粒以相衬显微镜图像的形式显示在生物医学研究中心(CRB)的网站上(两次调查),并根据图像和简短的临床病史诊断临床病例(两次调查)。然后对每个调查的结果进行评分和评论。在 20 年的时间里,共展示了 298 张图像:90 个细胞(9 种类型)、23 个脂质(5 种类型)、87 个铸型(21 种类型)、53 个晶体(14 种类型)、22 个微生物(5 种类型)和 23 个污染物(9 种类型)。此外,还向参与者展示了 27 个临床病例,涵盖了广泛的不同复杂程度的疾病。

结果

鉴定:在尿液颗粒类别中,微生物的正确鉴定率(每个颗粒从正确答案+部分正确答案的总和中获得)非常高(平均值±标准差:96.2±3.5%),脂质(88.0±11.8%)和晶体(87.0±16.5%)紧随其后,依次为细胞(82.1±15.9%)、铸型(81.8±14.8%)和污染物(76.7±22.1%)。临床关联(n=67):正确答案率为 93.5±5.7%,除一种临床关联(即急性肾小球肾炎:55.4%)外,所有临床关联的正确答案率均为 100%。临床病例:在整个调查过程中,由于总体颗粒错误识别率,只有 59.8±17.1%(范围 32.5-88.7%)的参与者能够进行临床诊断。其中,88.7±10.6%(范围 59.9-99.3%)能够指出正确的诊断。

结论

我们的计划可用作提高尿液颗粒识别能力和了解其临床意义的工具,并鼓励实验室医学专家将尿液发现与其他实验室数据和临床病史相关联,这提高了日常工作的价值。