Suppr超能文献

Comparison of glottic areas measured by acoustic reflections vs. computerized tomography.

作者信息

D'Urzo A D, Rubinstein I, Lawson V G, Vassal K P, Rebuck A S, Slutsky A S, Hoffstein V

机构信息

Department of Medicine, St. Michael's Hospital, Toronto, Ontario, Canada.

出版信息

J Appl Physiol (1985). 1988 Jan;64(1):367-70. doi: 10.1152/jappl.1988.64.1.367.

Abstract

We compared measurements of glottic area obtained by acoustic reflection technique with anatomically equivalent area measured from computerized tomographic (CT) scans of the neck in 11 subjects with glottic pathology. Both measurements were performed in the supine position during tidal breathing at functional residual capacity. We found excellent agreement in glottic areas obtained by both methods: the mean (+/- SD) values were 1.8 +/- 0.8 cm2 for the acoustic method and 1.7 +/- 0.9 cm2 for the CT method. Linear regression analysis revealed the following relationship between the area measured by acoustic technique (AAC) and that measured by CT (ACT): AAC = 0.81.ACT + 0.36. There was a significant correlation between the two measurements of glottic area (r = 0.95, P less than 0.0001). We conclude that the acoustic reflection technique may be used reliably in clinical and physiological studies concerned with glottic geometry.