Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.
Shanghai Institute of Medical Imaging, Shanghai, China.
BMC Med Imaging. 2021 Feb 11;21(1):24. doi: 10.1186/s12880-021-00559-7.
Coronary CT angiography (CCTA) is a complicated CT exam in comparison to other CT protocols. Exam success highly depends on image assessment of experienced radiologist and the procedure is often time-consuming. This study aims to evaluate feasibility of automatic CCTA reconstruction in 0.25 s rotation time, 16 cm coverage CT scanner with best phase selection and AI-assisted motion correction.
CCTA exams of 90 patients with heart rates higher than 75 bpm were included in this study. Two image series were reconstructed-one at automatically selected phase and another with additional motion correction. All reconstructions were performed without manual interaction of radiologist. A four-point Likert scale rating system was used to evaluate the image quality of coronary artery segment by two experienced radiologists, according to the 18-segment model. Analysis was done on per-segment basis.
Total 1194 out of the 1620 segments were identified for quality evaluation in 90 patients. After automatic best phase selection, 1172 segments (98.3%) were rated as having diagnostic image quality (scores 2-4) and the average score is 3.64 ± 0.55. When motion corrections were applied, diagnostic segment number increases to 1192 (99.8%) and the average score is 3.85 ± 0.37.
With the help of 0.25 s rotation speed, 16-cm z-coverage and AI-assisted motion correction algorithm, CCTA exam reconstruction could be performed with minimum radiologist involvement and still meet image quality requirement.
与其他 CT 方案相比,冠状动脉 CT 血管造影(CCTA)是一项复杂的 CT 检查。检查的成功高度依赖于有经验的放射科医生的图像评估,而且该过程通常很耗时。本研究旨在评估在 0.25 秒旋转时间、16 厘米覆盖范围 CT 扫描仪上进行自动 CCTA 重建的可行性,该扫描仪具有最佳相位选择和 AI 辅助运动校正功能。
本研究纳入了 90 例心率高于 75 次/分的 CCTA 检查患者。重建了两个图像系列,一个是在自动选择的相位下重建的,另一个是在附加运动校正下重建的。所有重建均无需放射科医生的手动干预。两位有经验的放射科医生使用四点 Likert 量表评分系统,根据 18 节段模型,对冠状动脉节段的图像质量进行评估。分析基于每个节段进行。
在 90 例患者中,总共对 1620 个节段中的 1194 个进行了质量评估。在自动最佳相位选择后,1172 个节段(98.3%)被评为具有诊断性图像质量(评分 2-4),平均评分为 3.64±0.55。当应用运动校正时,诊断节段数量增加到 1192(99.8%),平均评分增加到 3.85±0.37。
在 0.25 秒旋转速度、16 厘米 z 覆盖范围和 AI 辅助运动校正算法的帮助下,CCTA 检查重建可以在最小的放射科医生参与下进行,并且仍然满足图像质量要求。