Robbins A H, Vincent M E, Shaffer K, Maietta R, Srinivasan M K
Department of Radiology, Boston Veterans Administration Medical Center, MA 02130.
Radiology. 1988 Jun;167(3):853-5. doi: 10.1148/radiology.167.3.3363152.
A prototype 5,000-word recognizer for the generation of radiologic reports by voice entry was evaluated. The system had a capacity sufficient enough to include all radiologic examinations and all desired words in one lexicon. The lack of such a capacity had been identified as a major limitation of a 1,000-word system previously evaluated. Overall reliability in word recognition was 98%. The device may be widely applicable for use in any radiology practice.
对一个用于通过语音输入生成放射学报告的5000词原型识别器进行了评估。该系统的容量足够大,能够在一个词汇表中包含所有放射学检查和所有所需词汇。之前评估的一个1000词系统的主要局限性就在于缺乏这样的容量。单词识别的总体可靠性为98%。该设备可能广泛适用于任何放射学实践。