在功能性伸展测试中,使用Image J测量伸展距离和运动角度的可靠性。

Reliability of measurement using Image J for reach distance and movement angles in the functional reach test.

作者信息

Suzuki Takayuki, Hashisdate Hiroyuki, Fujisawa Yuhki, Yatsunami Mitsunobu, Ota Tomohiro, Shimizu Natsuki, Betsuyaku Tetsuo

机构信息

Department of Rehabilitation, Tokyo Tenshi Hospital: 50-1 Kamiichibukata-cho, Hachioji-city, Tokyo 193-0811, Japan.

Department of Rehabilitation Science, Graduate School of Health Sciences, Kyorin University, Japan.

出版信息

J Phys Ther Sci. 2021 Feb;33(2):112-117. doi: 10.1589/jpts.33.112. Epub 2021 Feb 13.

Abstract

[Purpose] The purpose of this study was to examine the test-retest reliability and minimal detectable change (MDC) of reach distance and movement angle analyses using Image J. [Participants and Methods] Thirty-eight healthy young males performed the functional reach test (FRT) twice, and their reach movements were recorded using a digital video camera. Image J was used to combine the digital photographs taken at the start position and maximum reach and to measure each movement. The measurements recorded were the movement distance of the third metacarpal bone (reach distance), anterior-superior iliac spine, and trochanter major, and the angles recorded were the acromion-malleolus lateralis, acromion-trochanter major, and trochanter major-malleolus lateralis. The reliability of all the measurements was analyzed using intraclass correlation coefficients (ICCs), Bland-Altman plots, and MDCs. [Results] The ICCs (1, 1) were >0.80 for all the outcomes. The Bland-Altman analysis revealed no systematic bias in any outcome. The MDC of reach distance was 18.3 mm. [Conclusion] Measurement using Image J for reach distance and movement angles in the FRT showed acceptable high test-retest reliability. Measurement of the FRT and the MDC calculated in this study could be used as a reference for further research.

摘要

[目的] 本研究旨在探讨使用Image J对伸展距离和运动角度分析进行重测信度及最小可检测变化(MDC)。[参与者与方法] 38名健康年轻男性进行两次功能性伸展测试(FRT),其伸展动作使用数码摄像机记录。使用Image J将起始位置和最大伸展时拍摄的数码照片合并,并测量每个动作。记录的测量值为第三掌骨的移动距离(伸展距离)、髂前上棘和大转子,记录的角度为肩峰-外踝、肩峰-大转子和大转子-外踝。使用组内相关系数(ICC)、Bland-Altman图和MDC分析所有测量的信度。[结果] 所有结果的ICC(1,1)均>0.80。Bland-Altman分析显示任何结果均无系统偏差。伸展距离的MDC为18.3 mm。[结论] 在FRT中使用Image J测量伸展距离和运动角度显示出可接受的高重测信度。本研究中计算的FRT测量值和MDC可作为进一步研究的参考。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2e5a/7897527/fa06b162b1fb/jpts-33-112-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验