比较巴斯科面具®和气管内导管对鼻中隔成形术患者血流动力学和呼吸参数的影响。

Comparison of the Baska Mask® and Endotracheal Tube on Hemodynamic and Respiratory Parameters in Septoplasty Cases.

机构信息

Department of Anesthesia and Reanimation, Bandırma State Hospital, Balıkesir, Turkey.

Department of Otolaryngology, Bandırma State Hospital, Balıkesir, Turkey.

出版信息

Prague Med Rep. 2021;122(1):5-13. doi: 10.14712/23362936.2021.1.

Abstract

Laryngeal mask (LM) types have been used as an airway device for an alternative to the standard endotracheal tube (ETT). One of the novel type of LM, the Baska Mask®, can be a safe alternative among the airway devices. The purpose of this study is to compare the effects of the new generation supraglottic airway device the Baska Mask® and the ETT on hemodynamic parameters (heart rate, mean arterial pressure), airway pressure and end tidal carbon dioxide (EtCO2) in patients undergoing general anesthesia. After the approval of the ethics committee, 70 patients who underwent septoplasty were included in the study. Written informed consent forms were taken from these patients. Demographic data of the patients were recorded. Hemodynamic data of patients were measured and recorded preoperative, during induction, at the time of intubation 1th, 3th and 5th minute and during extubation. Also, airway pressure and EtCO2 values of the patients were measured and recorded at the time of intubation, 1th, 3th and 5th minutes. Demographic data were similar in both groups. Mean arterial pressure, heart rate and airway pressure were lower in the group 2 (the Baska Mask® group) than in the group 1 (ETT group) and the difference was statistically significant (p<0.05). EtCO2 values were similar in both groups. No patients had tube leakage. In terms of hemodynamic and respiratory parameters the Baska Mask® is more advantageous than the ETT in short-term surgeries.

摘要

喉罩(LM)已被用作替代标准气管内管(ETT)的气道装置。新型 LM 之一的 Baska Mask®可以作为气道装置的安全替代选择。本研究的目的是比较新型的声门上气道装置 Baska Mask®和 ETT 对全身麻醉患者的血流动力学参数(心率、平均动脉压)、气道压和呼气末二氧化碳(EtCO2)的影响。在伦理委员会批准后,将 70 名接受鼻中隔成形术的患者纳入研究。从这些患者处获得了书面知情同意书。记录患者的人口统计学数据。测量并记录患者的血流动力学数据,包括术前、诱导时、插管后 1 分钟、3 分钟和 5 分钟以及拔管时。同时,在插管时、插管后 1 分钟、3 分钟和 5 分钟测量并记录气道压和 EtCO2 值。两组的人口统计学数据相似。与第 1 组(ETT 组)相比,第 2 组(Baska Mask®组)的平均动脉压、心率和气道压较低,差异具有统计学意义(p<0.05)。两组的 EtCO2 值相似。无患者出现管漏。在短期手术中,Baska Mask®在血流动力学和呼吸参数方面优于 ETT。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验