Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, 514-8507, Japan.
Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA.
Eur Spine J. 2021 May;30(5):1355-1364. doi: 10.1007/s00586-021-06776-6. Epub 2021 Mar 2.
Two-dimensional (2D) analyses of intervertebral disc (IVD) height and foramen measurements following lateral lumbar interbody fusion (LLIF) have been reported. However, three-dimensional (3D) morphometric analysis of intervertebral structure using 3D computed tomography (3D CT) provides increased precision for measuring morphological changes. The purpose of this study was to evaluate 3D changes of lumbar IVD height and foramen diameter in degenerative lumbar disease patients following LLIF.
Subject-based 3D CT lumbar models were created for 26 patients before and following LLIF. IVD height (whole and five anatomical zones) and foramen diameter (minimum and maximum) were measured based on the model using custom software. The sagittal placement of cages (SPC) and cross-sectional area of the thecal sac (CSA) were measured. Changes in these parameters by LLIF were quantified and statistically analysed.
Following LLIF, disc height increased by an average of 2.9 mm (P < 0.01). Post-operative measurements of both minimum and maximum diameters of the foramen were significantly increased by 1.0 mm and 1.9 mm, respectively (P < 0.01). Change in maximum foramen diameter was significantly correlated with change in disc height (P < 0.05). The SPC was significantly correlated with the changes in disc height and foraminal diameters (P < 0.05, respectively). No significant change between the change in disc height and CSA was found.
This preliminary study quantifies disc height and foramen diameter changes in 3D following LLIF. The presented data provide baseline intervertebral changes for future comparisons with follow-up studies and clinical outcomes.
Diagnostic: individual cross-sectional studies with the consistently applied reference standard and blinding.
已有研究报道了腰椎侧方椎间融合术(LLIF)后椎间盘(IVD)高度和椎间孔测量的二维(2D)分析。然而,使用三维(3D)计算机断层扫描(3D CT)对椎间结构进行三维形态计量分析可提高测量形态变化的精度。本研究旨在评估退行性腰椎疾病患者行 LLIF 后腰椎 IVD 高度和椎间孔直径的 3D 变化。
为 26 例患者创建了基于个体的术前和术后腰椎 3D CT 模型。使用定制软件,根据模型测量 IVD 高度(整个和五个解剖区)和椎间孔直径(最小和最大)。测量了椎间笼的矢状位置(SPC)和硬脊膜囊的横截面积(CSA)。定量分析了 LLIF 对这些参数的变化,并进行了统计学分析。
LLIF 后,椎间盘高度平均增加了 2.9 毫米(P<0.01)。术后最小和最大椎间孔直径分别显著增加了 1.0 毫米和 1.9 毫米(P<0.01)。最大椎间孔直径的变化与椎间盘高度的变化显著相关(P<0.05)。SPC 与椎间盘高度和椎间孔直径的变化显著相关(P<0.05,分别)。未发现椎间盘高度和 CSA 变化之间有显著差异。
本初步研究定量分析了 LLIF 后 3D 下椎间盘高度和椎间孔直径的变化。所提供的数据为未来与随访研究和临床结果进行比较提供了椎间变化的基线。
证据水平 I:诊断:具有一致应用参考标准和盲法的个体横断面研究。