Ma Tuo, Cao Li Xiu, Li Hui Ju, Ren Hong Liang, Chen Da Peng, Gao Yuan, Li Zhi Dong, Zhao Xin Bin, Dong Si Qi
Department of CT,North China University of Science and Technology Affiliated Hospital,Tangshan,Heibei 063000,China.
Department of CT, Tangshan People's Hospital,Tangshan,Hebei 063000,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2021 Feb 28;43(1):53-56. doi: 10.3881/j.issn.1000-503X.12514.
Objective To compare the differences of energy spectrum CT between small cell lung cancer(SCLC)with mediastinal lymph node metastasis and mediastinal sarcoidosis.Methods Twenty-five SCLC patients with mediastinal lymph node metastasis(SCLC group)and 26 patients with mediastinal sarcoidosis(sarcoidosis group)confirmed by bronchoscopy and biopsy in Tangshan People's Hospital from January 2018 to June 2019 were selected as the research objects.The CT value,iodine concentration,water concentration and energy spectrum curve slope under different single energy levels were compared between SCLC group and sarcoidosis group.Results The single-energy CT values of 40-80 keV segments in the arterial phase of the SCLC group were significantly higher than those in the sarcoidosis group(all P <0.05).The single-energy CT values of 90-140 keV segments were not significantly different from those in the sarcoidosis group(all P >0.05).The single-energy CT values of 40-90 keV segments in venous phase of the SCLC group were significantly higher than those of the sarcoidosis group(all P <0.05),and the single-energy CT values of 100-140 keV segments were not significantly different from those of the sarcoidosis group(all P >0.05).The concentrations of iodine in the arterial phase and venous phase of the SCLC group were(11.56±4.06)μg/cm and(13.39±0.87)μg/cm ,respectively,which were significantly higher than those [(4.43±3.85)μg/cm ,t=11.564,P=0.026;(7.23±2.71)μg/cm ,t=13.653,P=0.021] in the sarcoidosis group.The concentrations of water in the arterial and venous phases of the SCLC group were(1040.67±5.62)mg/cm and(1035.23±8.57)mg/cm ,respectively,which showed no statistically significant difference compared with those [(1028.87±6.94)mg/cm ,t=3.155,P=1.861;(1021.53±4.68)mg/cm ,t=3.265,P=1.687] in the sarcoidosis group.The slopes of energy spectrum curve at 40-70 keV,70-100 keV and 100-140 keV in venous phase of the SCLC group were significantly higher than those of the sarcoidosis group(all P <0.05),whereas they showed no significant difference between the two groups in arterial phase(all P >0.05).Conclusion The differences between SCLC with mediastinal lymph node metastasis and mediastinal sarcoidosis can be shown on the single-energy CT values of 40-80 keV in arterial phase and 40-90 keV in venous phase,iodine concentrations in arterial phase and venous phase,and the slope of energy spectrum curve in venous phase.
目的 比较小细胞肺癌(SCLC)伴纵隔淋巴结转移与纵隔结节病在能谱CT上的差异。方法 选取2018年1月至2019年6月在唐山市人民医院经支气管镜及活检确诊的25例SCLC伴纵隔淋巴结转移患者(SCLC组)和26例纵隔结节病患者(结节病组)作为研究对象。比较SCLC组和结节病组不同单能量水平下的CT值、碘浓度、水浓度及能谱曲线斜率。结果 SCLC组动脉期40~80 keV段的单能量CT值显著高于结节病组(均P<0.05)。90~140 keV段的单能量CT值与结节病组差异无统计学意义(均P>0.05)。SCLC组静脉期40~90 keV段的单能量CT值显著高于结节病组(均P<0.05),100~140 keV段的单能量CT值与结节病组差异无统计学意义(均P>0.05)。SCLC组动脉期和静脉期碘浓度分别为(11.56±4.06)μg/cm 和(13.39±0.87)μg/cm ,显著高于结节病组[(4.43±3.85)μg/cm ,t=11.564,P=0.026;(7.23±2.71)μg/cm ,t=13.653,P=0.021]。SCLC组动脉期和静脉期水浓度分别为(1040.67±5.62)mg/cm 和(1035.23±8.57)mg/cm ,与结节病组[(1028.87±6.94)mg/cm ,t=3.155,P=1.861;(1021.53±4.68)mg/cm ,t=3.265,P=1.687]比较差异无统计学意义。SCLC组静脉期40~70 keV、70~100 keV及100~140 keV能谱曲线斜率显著高于结节病组(均P<0.05),而动脉期两组差异无统计学意义(均P>0.05)。结论 SCLC伴纵隔淋巴结转移与纵隔结节病在动脉期40~80 keV、静脉期40~90 keV的单能量CT值、动脉期和静脉期碘浓度及静脉期能谱曲线斜率上存在差异。