Suppr超能文献

口轮匝肌内皮下针在术中神经生理监测时的锐器伤。

Sharps Injuries Related to Subdermal Needles in the Orbicularis Oris During Intraoperative Neurophysiologic Monitoring.

机构信息

Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, U.S.A.; and.

Stanford Healthcare, Stanford, California, U.S.A. Dr. Joshi is now with the Department of Neurology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, U.S.A.

出版信息

J Clin Neurophysiol. 2022 Nov 1;39(7):643-646. doi: 10.1097/WNP.0000000000000835. Epub 2021 Mar 18.

Abstract

PURPOSE

Little is known about the incidence and nature of sharps injuries caused by subdermal intraoperative neurophysiologic monitoring (IONM) needle electrodes. In their institution, the authors observed a series of sharps injuries attributed to placement of needles in the orbicularis oris (OO).

METHODS

One large academic institution's sharps injury monitoring database was queried for all reported events over 3 years. The de-identified list was filtered for sharps events occurring in the operating room, and the descriptions of the sharps injuries were individually evaluated. Interventions were performed to attempt to decrease the number of sharps injuries from IONM needles, particularly those placed in OO. Similar data were then collected for 3 months post-intervention.

RESULTS

Pre-intervention, 327 sharps injuries were reported over the span of 3 years, of which 13 (4.0%) were attributed to IONM needles not in OO and 5 (1.5%) were attributed to IONM needles in OO. Post-intervention, 41 sharps injuries were reported in 3 months, of which 5 (12.2%) were attributed to IONM needles not in OO and 1 (2.4%) was attributed to needles in OO.

CONCLUSIONS

The placement of subdermal needles in the OO presents a disproportionately high risk of sharps injury. Interventions were performed to attempt to decrease the rate of sharps injuries from needles in OO; the post-intervention increase in events was likely skewed by small sample sizes. The implementation of these changes and the ongoing surveillance of injury cases may be important data to help decrease the number of sharps injuries attributed to IONM needles.

摘要

目的

皮下术中神经生理监测 (IONM) 针电极引起的锐器伤的发生率和性质知之甚少。在作者所在机构,作者观察到一系列归因于放置在口轮匝肌 (OO) 中的针的锐器伤。

方法

在 3 年期间,通过查询一家大型学术机构的锐器伤监测数据库,查询所有报告的事件。对手术室中发生的锐器伤事件进行了去识别列表过滤,并单独评估了锐器伤的描述。进行了干预措施,试图减少 IONM 针造成的锐器伤数量,特别是放置在 OO 中的针。然后收集了类似的数据进行干预后的 3 个月。

结果

在干预前的 3 年期间报告了 327 例锐器伤,其中 13 例(4.0%)归因于未放置在 OO 中的 IONM 针,5 例(1.5%)归因于放置在 OO 中的 IONM 针。干预后 3 个月报告了 41 例锐器伤,其中 5 例(12.2%)归因于未放置在 OO 中的 IONM 针,1 例(2.4%)归因于放置在 OO 中的针。

结论

在 OO 中皮下放置针会带来不成比例的高锐器伤风险。进行了干预措施以试图降低 OO 中针引起的锐器伤发生率;干预后的事件增加可能是由于样本量小而产生的偏差。实施这些更改并持续监测伤害案件可能是有助于减少归因于 IONM 针的锐器伤数量的重要数据。