Tissue reaction to implant corrosion in 38 internal fixation devices.

作者信息

Thomas K A, Cook S D, Harding A F, Haddad R J

机构信息

Department of Orthopedic Surgery, Tulane University School of Medicine, New Orleans, LA 70112.

出版信息

Orthopedics. 1988 Mar;11(3):441-51. doi: 10.3928/0147-7447-19880301-09.

DOI:10.3928/0147-7447-19880301-09
PMID:3368412
Abstract

The corrosion characteristics, metallurgical properties, and clinical performance of 38 retrieved internal fixation devices were correlated with the tissue reaction to these devices. Metallurgical parameters included thin and heavy inclusion content, Rockwell hardness, and grain size. The excised fibrous tissue strip was directly overlying each plate at removal and sectioned between screw-hole sites. The material studied from the 38 plates consisted of 201 screw-hole junctions with associated tissue biopsy sites. Clinical histories were obtained on all 38 patients with hardware removal. The average age at the time of plate insertion was 35.6 years (range, 4 to 75 years). Insertion diagnoses included acute trauma (35 patients), joint dislocations (two patients), and fracture nonunion (one patient). The devices included seven upper extremity bone plates, 19 lower extremity bone plates, and 12 hip screw plates. The devices remained in situ an average of 20.4 months (range, 3 to 60 months). Routine asymptomatic removals were performed on 17 of the patients, while the remaining 21 patients were symptomatic at the time of removal. Included in the reasons for symptomatic removal were pain associated with the implant (eight patients), nonunion (four patients), bursae prominence (three patients), and implant breakage (two patients). Significant correlations were found between average tissue reaction scores and average crevice corrosion scores; a trend of increasing average tissue reaction scores with increasing average screw surface corrosion scores also was observed for the 38 devices, although this relationship was not significant. Average crevice corrosion scores and average screw surface corrosion scores were highly correlated for all removals, and for the asymptomatic and symptomatic removal groups. The metallurgical parameters of thin inclusion content and heavy inclusion content also were significantly correlated for all removals, as well as for symptomatic removals. Similarly, significant correlations were found between the individual tissue reaction scores and crevice corrosion scores from the 201 individual sites, again for all devices and for the asymptomatic and symptomatic removal groups. Tissue reaction scores and time in situ showed significant correlation, with tissue reaction decreasing over time. Crevice corrosion and screw surface corrosion scores were not significantly related to time in situ. The results of this study indicate that there is considerable tissue reaction to the corrosion products of this material.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

相似文献

1
Tissue reaction to implant corrosion in 38 internal fixation devices.
Orthopedics. 1988 Mar;11(3):441-51. doi: 10.3928/0147-7447-19880301-09.
2
The in vivo performance of 250 internal fixation devices: a follow-up study.250种内固定装置的体内性能:一项随访研究。
Biomaterials. 1987 May;8(3):177-84. doi: 10.1016/0142-9612(87)90060-3.
3
A clinical and metallurgical analysis of retrieved Jewett and Richards hip plate devices.
Clin Orthop Relat Res. 1985 May(195):261-9.
4
Clinical and metallurgical analysis of retrieved internal fixation devices.
Clin Orthop Relat Res. 1985 Apr(194):236-47.
5
Correlation of tissue reaction to corrosion in osteosynthetic devices.骨内固定装置中组织反应与腐蚀的相关性。
J Biomed Mater Res. 1984 Sep;18(7):817-28. doi: 10.1002/jbm.820180712.
6
Technical problems and complications in the removal of the less invasive stabilization system.微创稳定系统取出术中的技术问题及并发症。
J Orthop Trauma. 2010 Jun;24(6):369-73. doi: 10.1097/BOT.0b013e3181c29bf5.
7
Functional load of plates in fracture fixation in vivo and its correlate in bone healing.体内骨折固定中钢板的功能负荷及其与骨愈合的相关性。
Injury. 2000 May;31 Suppl 2:S-B37-50. doi: 10.1016/s0020-1383(00)80042-x.
8
Complications during removal of conventional versus locked compression plates: is there a difference?拆除传统钢板与锁定加压钢板时的并发症:有差异吗?
Int Orthop. 2017 Aug;41(8):1513-1519. doi: 10.1007/s00264-016-3352-7. Epub 2016 Dec 24.
9
How difficult is titanium plate and screw implant removal? A retrospective case series.钛板和螺丝钉取出困难吗?一项回顾性病例系列研究。
Injury. 2024 Nov;55(11):111824. doi: 10.1016/j.injury.2024.111824. Epub 2024 Aug 13.
10
Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.基于LAE442的接骨板-螺钉系统在体外骨模型中的降解行为。
Mater Sci Eng C Mater Biol Appl. 2015 Apr;49:305-315. doi: 10.1016/j.msec.2015.01.019. Epub 2015 Jan 7.

引用本文的文献

1
Indications for implant removal after fracture healing: a review of the literature.骨折愈合后植入物取出的适应证:文献综述
Eur J Trauma Emerg Surg. 2013 Aug;39(4):327-37. doi: 10.1007/s00068-013-0283-5. Epub 2013 Apr 12.
2
Fixation of Mitchell's osteotomy with bioabsorbable pins for treatment of hallux valgus deformity.使用生物可吸收针固定米切尔截骨术治疗拇外翻畸形。
Int Orthop. 2009 Jun;33(3):701-6. doi: 10.1007/s00264-008-0664-2. Epub 2008 Oct 28.
3
Late implant infections caused by Propionibacterium acnes in scoliosis surgery.
脊柱侧弯手术中痤疮丙酸杆菌引起的晚期植入物感染。
Eur Spine J. 2005 Oct;14(8):783-8. doi: 10.1007/s00586-004-0854-6. Epub 2005 Apr 20.