Department of Plastic Surgery, University of Texas Southwestern Medical Center, Dallas, TX, USA.
Department of Plastic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
Aesthet Surg J. 2021 Oct 15;41(11):NP1647-NP1656. doi: 10.1093/asj/sjab107.
Laxity of the submental area is a common cosmetic complaint of the aging population.
The aim of this study was to determine the safety and effectiveness of a temperature-controlled, minimally invasive percutaneous monopolar radiofrequency device to improve dermal laxity and achieve lift.
A total of 72 subjects (35-65 years old) with mild to moderate skin laxity in the submental area were included in this single-center prospective study. All subjects received 1 treatment at baseline with an average subdermal temperature of 63°C. The primary endpoint was the proportion of subjects with at least a 20-mm2 decrease in surface area at Day 90 based on 3-dimensional photography. Secondary endpoints included skin elasticity measured by Cutometer, assessment by a blinded physician panel from 2-dimensional photographs, and physician- and subject-reported outcomes.
At Day 90, 72.1% (95% CI: 62.2%-84.0%; P < 0.001) of subjects achieved at least a 20-mm2 lift of the submental area. All Cutometer-measured skin elasticity values (R2, R5, R7) showed significant improvement by 180 days. The independent panel graded 74.2% of subjects as "improved" at 90 days (95% CI: 62.0%-84.2%; P < 0.001). The treatment was well tolerated, and only 1 possibly related serious adverse event was reported (pharyngeal inflammation).
Treatment with temperature-controlled monopolar radiofrequency alone is a safe and effective treatment to achieve submental lift for at least 6 months.
颏下区域的松弛是老龄化人群常见的美容抱怨。
本研究旨在确定一种温度控制、微创性单极射频设备的安全性和有效性,以改善皮肤松弛并实现提升。
共有 72 名(35-65 岁)颏下区域有轻度至中度皮肤松弛的受试者参与了这项单中心前瞻性研究。所有受试者在基线时接受 1 次治疗,平均皮下温度为 63°C。主要终点是根据三维摄影,在第 90 天至少有 20mm²的表面积减少的受试者比例。次要终点包括通过 Cutometer 测量的皮肤弹性、来自二维照片的盲法医生小组评估以及医生和受试者报告的结果。
在第 90 天,72.1%(95%置信区间:62.2%-84.0%;P < 0.001)的受试者至少实现了 20mm²的颏下区域提升。所有 Cutometer 测量的皮肤弹性值(R2、R5、R7)在 180 天时均显示出显著改善。独立小组在第 90 天评定 74.2%的受试者为“改善”(95%置信区间:62.0%-84.2%;P < 0.001)。该治疗耐受良好,仅报告了 1 例可能相关的严重不良事件(咽部炎症)。
单独使用温度控制单极射频治疗是一种安全有效的治疗方法,至少可在 6 个月内实现颏下提升。