Limbco Ltd, Plough Lane, Hereford, HR4 0EL, UK.
University of Oxford, Oxford, UK.
Cardiovasc Intervent Radiol. 2021 Jul;44(7):1103-1108. doi: 10.1007/s00270-021-02797-2. Epub 2021 Mar 11.
To investigate if the detergent sclerosant sodium tetradecyl sulfate (STS) is deactivated by the lipid-based contrast agent ethiodised oil.
3% STS was mixed with ethiodised oil and room air in a 2:1:4 ratio in two luer lock syringes and a three way connector and agitated to make foam (the Tessari technique) to replicate the clinical use of the products. The assay of STS in the mixture was assessed using the British Pharmacopoeia method. Briefly this is a manual titration method where the solution of STS is mixed with an indicator solution and titrated with hyamine solution of known concentration; the concentration of the STS can then be calculated with the titration results. To further mimic the clinical environment with the presence of blood, the effect of adding increasing amounts of albumin to the STS-ethiodised oil mixture was assessed.
The assay of STS in the solution after mixing with ethiodised oil was 3% indicating that the ethiodised oil did not deactivate the STS. The addition of albumin to the STS-contrast mixture resulted in near linear neutralisation of the STS with increasing concentrations in the same quantities as with STS alone.
The mixture of the lipid-based contrast agent ethiodised oil with the detergent sclerosant STS did not affect the availability of the sclerosant. The continued use of STS-ethiodised oil in the management of vascular malformations can be supported.
研究脂质造影剂碘油是否会使清洁剂硬化剂十四烷基硫酸钠(STS)失活。
将 3%STS 与碘油以 2:1:4 的比例混合于两个鲁尔锁注射器和三通连接器中,并与室内空气混合搅拌制成泡沫(Tessari 技术),以模拟产品的临床使用。采用英国药典法对混合物中的 STS 进行检测。简要地说,这是一种手动滴定法,将 STS 溶液与指示剂溶液混合,并与已知浓度的羟胺溶液滴定;然后可以根据滴定结果计算 STS 的浓度。为了进一步模拟临床环境中血液的存在,评估了向 STS-碘油混合物中添加不同量白蛋白的效果。
与碘油混合后的 STS 溶液的测定值为 3%,表明碘油不会使 STS 失活。向 STS-对比混合物中添加白蛋白会导致 STS 近乎线性中和,且随着与 STS 相同量的白蛋白的增加而增加。
脂质造影剂碘油与清洁剂硬化剂 STS 的混合物不会影响硬化剂的可用性。可以支持继续在血管畸形的治疗中使用 STS-碘油混合物。