Department of Anesthesiology, Albany Medical College, Albany, NY, USA.
J Hosp Infect. 2021 Jul;113:130-144. doi: 10.1016/j.jhin.2021.03.005. Epub 2021 Mar 11.
Injection safety is essential to reduce the risk of healthcare-associated infections (HAIs) when accessing vascular catheters. This general review evaluates the contamination of vascular catheter access ports and associated HAIs in acute care settings, focusing on open lumen stopcocks (OLSs) and disinfectable needleless closed connectors (DNCCs). PubMed was searched from January 2000 to February 2021. OLS intraluminal surfaces are frequently contaminated during patient care, increasing the risk of HAIs, and neither an isopropyl alcohol (IPA) pad nor a port-scrub device can reduce contamination effectively. In contrast, DNCCs can be disinfected, with most studies indicating less intraluminal contamination than OLSs and some studies showing decreased HAIs. While the optimal DNCC design to reduce HAIs needs to be determined, DNCCs alone or stopcocks with a DNCC bonded to the injection port should replace routine use of OLSs, with OLSs restricted to use in sterile fields. Compliance with disinfection is essential immediately before use of a DNCC as use of a non-disinfected DNCC can have equivalent or greater risk of HAIs compared with use of an OLS. The recommendations for access port disinfection in selected national and international guidelines vary. When comparing in-vitro studies, clinical studies and published guidelines, consensus is lacking; therefore, additional studies are needed, including large randomized controlled trials. IPA caps disinfect DNCCs passively, eliminate scrubbing and provide a contamination barrier; however, their use in neonates has been questioned. Further study is needed to determine whether IPA caps are more efficacious than scrubbing with disinfectant to decrease HAIs related to use of central venous, peripheral venous and arterial catheters.
注射安全对于降低血管内导管相关的医源性感染(HAI)风险至关重要。本综述评估了在急性护理环境中血管导管接入端口的污染和相关 HAI,重点关注开放式内腔管塞(OLS)和可消毒的无针密闭连接器(DNCC)。使用 PubMed 数据库,检索时间范围为 2000 年 1 月至 2021 年 2 月。OLS 的管腔内壁在患者护理过程中经常受到污染,增加了 HAI 的风险,异丙醇(IPA)垫或端口擦洗器均不能有效减少污染。相比之下,DNCC 可以进行消毒,大多数研究表明其管腔污染程度低于 OLS,有些研究表明 HAI 减少。虽然需要确定降低 HAI 的最佳 DNCC 设计,但应单独使用 DNCC 或带 DNCC 的管塞替代常规使用的 OLS,在无菌区域限制使用 OLS。在使用 DNCC 之前,必须遵守消毒规范,因为与使用 OLS 相比,使用未消毒的 DNCC 可能具有相同或更大的 HAI 风险。一些国家和国际指南中关于接入端口消毒的建议有所不同。在比较体外研究、临床研究和已发表的指南时,缺乏共识;因此,需要进行更多的研究,包括大样本随机对照试验。IPA 帽可被动消毒 DNCC,消除擦洗并提供污染屏障;然而,IPA 帽在新生儿中的使用受到质疑。需要进一步研究以确定 IPA 帽是否比用消毒剂擦洗更有效,以减少与使用中心静脉、外周静脉和动脉导管相关的 HAI。