Suppr超能文献

新型二极管泵浦脉冲铥:钇铝石榴石激光与连续波铥:钇铝石榴石和脉冲钬:钇铝石榴石激光的组织效应比较。

Tissue effects of a newly developed diode pumped pulsed Thulium:YAG laser compared to continuous wave Thulium:YAG and pulsed Holmium:YAG laser.

机构信息

Department of Urology and Urologic Oncology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.

Hannover Medical School, Institute for Pathology, Hannover, Germany.

出版信息

World J Urol. 2021 Sep;39(9):3503-3508. doi: 10.1007/s00345-021-03634-4. Epub 2021 Mar 16.

Abstract

PURPOSE

The objective of this study is to evaluate the laser-tissue effects of laser radiation emitted by a newly developed high frequency pulsed Tm:YAG laser in comparison to the continuous wave Tm:YAG laser and the pulsed Ho:YAG laser.

METHODS

Ex-vivo experiments were performed on freshly slaughtered porcine kidneys in a physiological saline solution. Experiments were performed using two different laser devices in different settings: A Tm:YAG laser was operated in a pulsed mode up to 300 Hz and in a continuous wave (CW) mode. Results were compared with a 100 W standard pulsed Ho:YAG laser system. Comparative tissue experiments were performed at 5 W, 40 W and 80 W. The incision depth and the laser damage zone were measured under a microscope using a calibrated ocular scale.

RESULTS

Increased laser power resulted in increased incision depth and increased laser damage zone for all investigated lasers in this set-up. The Ho:YAG created the largest combined tissue effect at the 5 W power setting and seems to be the least controllable laser at low power for soft tissue incisions. The CW Tm:YAG did not incise at all at 5 W, but created the largest laser damage zone. For the new pulsed Tm:YAG laser the tissue effect grew evenly with increasing power.

CONCLUSION

Among the investigated laser systems in this setting the pulsed Tm:YAG laser shows the most controllable behavior, insofar as both the incision depth and the laser damage zone increase evenly with increasing laser power.

摘要

目的

本研究旨在评估一种新开发的高频脉冲 Tm:YAG 激光与连续波 Tm:YAG 激光和脉冲 Ho:YAG 激光相比的激光组织效应。

方法

在生理盐溶液中对新鲜屠宰的猪肾进行离体实验。使用两种不同的激光设备在不同的设置下进行实验:Tm:YAG 激光以高达 300 Hz 的脉冲模式和连续波(CW)模式运行。结果与 100 W 标准脉冲 Ho:YAG 激光系统进行比较。在 5 W、40 W 和 80 W 下进行比较组织实验。使用校准目镜标度在显微镜下测量切口深度和激光损伤区。

结果

在这种设置下,增加激光功率会导致所有研究的激光的切口深度和激光损伤区增加。在 5 W 的功率设置下,Ho:YAG 产生了最大的联合组织效应,并且似乎是低功率软组织切割中最不可控的激光。5 W 时 CW Tm:YAG 根本不切割,但产生了最大的激光损伤区。对于新的脉冲 Tm:YAG 激光,随着功率的增加,组织效应均匀增长。

结论

在这种设置下,在所研究的激光系统中,脉冲 Tm:YAG 激光表现出最可控的行为,因为切口深度和激光损伤区随着激光功率的增加而均匀增加。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/83bb/8510916/bea33a2fb73b/345_2021_3634_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验