School of Construction Engineering, Shandong University of Technology, Zibo, Shandong, China.
School of Architecture and Civil Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China.
PLoS One. 2021 Mar 17;16(3):e0248502. doi: 10.1371/journal.pone.0248502. eCollection 2021.
Composite pile foundation has been widely used in ground engineering. This composite pile foundation system has complex pile-soil interactions under seismic loading. The calculation of vertical bearing capacity of composite pile foundation is still an unsolved problem if the soil around piles is partially or completely liquefied under seismic loading. We have completed indoor shaking table model tests to measure the vertical bearing capacity in a liquefiable soil foundation under seismic loading. This paper will use a numerical approach to analyze the change of this vertical bearing capacity under seismic loading. Firstly, the Goodman contact element is improved to include the Rayleigh damping. Such an improvement can well describe the reflection and absorption of seismic waves at the interface of soil and piles. Secondly, the Biot's dynamic consolidation theory incorporated an elastoplastic model is applied to simulate the soil deformation and the generation and accumulation of pore water pressure under seismic loading. Thirdly, after verification with our indoor shaking table test data, this approach is used to investigate the effects of pile spacing on liquefaction resistance of the composite pile foundation in liquefiable soil. The time histories of pore water pressure ratio (PPR') are calculated for the liquefiable soil and the vertical bearing capacity in partially liquefied soil is calculated and compared with our indoor shaking table test data at the 3D, 3.5D, 4D, 5D and 6D cases (D is the pile diameter). It is found that the pile spacing has some influence on the extent of soil liquefaction between piles. The vertical bearing capacity varies with liquefaction extent of inter-pile soil. The optimization of pile spacing varies with liquefaction extent. These results may provide some reference for the design of composite pile foundation under seismic loading.
复合桩基础已广泛应用于岩土工程中。在地震荷载作用下,这种复合桩基础系统具有复杂的桩土相互作用。如果桩周土在地震作用下部分或完全液化,那么复合桩基础的竖向承载力计算仍然是一个未解决的问题。我们已经完成了室内振动台模型试验,以测量地震作用下可液化土基础中的竖向承载力。本文将采用数值方法分析地震作用下这种竖向承载力的变化。首先,改进 Goodman 接触单元以包含瑞利阻尼,这种改进可以很好地描述土与桩界面处地震波的反射和吸收。其次,应用包含弹塑性模型的 Biot 动力固结理论来模拟地震作用下土的变形和孔隙水压力的产生和积累。第三,在与室内振动台试验数据验证后,该方法用于研究桩间距对可液化土中复合桩基础抗液化能力的影响。计算了可液化土中的孔隙水压力比(PPR')时程,并计算了部分液化土中的竖向承载力,并与 3D、3.5D、4D、5D 和 6D 情况下(D 为桩径)的室内振动台试验数据进行了比较。结果表明,桩间距对桩间土的液化程度有一定影响。竖向承载力随桩间土液化程度而变化。桩间距的优化随液化程度而变化。这些结果可能为地震作用下复合桩基础的设计提供一些参考。